Intel SR1500AL User Guide - Page 55

Removing DIMMs, Installing or Replacing the Processor, Installing the Processor

Page 55 highlights

11. Replace the system's cover and reconnect the AC power cord(s). For instructions on installing the system's cover, see "Installing the System Cover". Removing DIMMs To remove a DIMM, follow these steps: 1. Observe the safety and ESD precautions in "Safety Information". 2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Remove the AC power cord(s) from the server. 4. Remove the server's cover. See the documentation that came with your server chassis for instructions on removing the server's cover. 5. Gently spread the retaining clips at each end of the socket. The DIMM lifts from the socket. 6. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package. 7. Reinstall and reconnect any parts you removed or disconnected to reach the DIMM sockets. 8. Replace the system's cover and reconnect the AC power cord(s). For instructions on installing the system's cover, see "Installing the System Cover". Installing or Replacing the Processor Caution: Processor must be appropriate: You may damage the server board if you install a processor that is inappropriate for your server. See "Server System References" for a link to the list of compatible processor(s). Caution: ESD and handling processors: Reduce the risk of electrostatic discharge (ESD) damage to the processor by doing the following: (1) Touch the metal chassis before touching the processor or server board. Keep part of your body in contact with the metal chassis to dissipate the static charge while handling the processor. (2) Avoid moving around unnecessarily. Caution: Protective socket cover needs to be removed for proper cooling of the processor; failure to remove the cover could result in damage to the system. Installing the Processor To install a processor, follow these instructions: 1. Observe the safety and ESD precautions in "Safety Information". 2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Disconnect the AC power cord(s) from the server. Intel® Server System SR1500AL User's Guide 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180

Intel
®
Server System SR1500AL User’s Guide
33
11.
Replace the system's cover and reconnect the AC power cord(s). For instructions on
installing the system's cover, see
“Installing the System Cover”
.
Removing DIMMs
To remove a DIMM, follow these steps:
1.
Observe the safety and ESD precautions in
“Safety Information”
.
2.
Turn off all peripheral devices connected to the server. Turn off the server.
3.
Remove the AC power cord(s) from the server.
4.
Remove the server's cover. See the documentation that came with your server
chassis for instructions on removing the server's cover.
5.
Gently spread the retaining clips at each end of the socket. The DIMM lifts from
the socket.
6.
Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static
package.
7.
Reinstall and reconnect any parts you removed or disconnected to reach the DIMM
sockets.
8.
Replace the system’s cover and reconnect the AC power cord(s). For instructions
on installing the system's cover, see
“Installing the System Cover”
.
Installing or Replacing the Processor
Caution:
Processor must be appropriate: You may damage the server board if you install a
processor that is inappropriate for your server. See
“Server System References”
for a link
to the list of compatible processor(s).
Caution:
ESD and handling processors: Reduce the risk of electrostatic discharge (ESD) damage to
the processor by doing the following: (1) Touch the metal chassis before touching the
processor or server board. Keep part of your body in contact with the metal chassis to
dissipate the static charge while handling the processor. (2) Avoid moving around
unnecessarily.
Caution:
Protective socket cover needs to be removed for proper cooling of the processor; failure to
remove the cover could result in damage to the system.
Installing the Processor
To install a processor, follow these instructions:
1.
Observe the safety and ESD precautions in
“Safety Information”
.
2.
Turn off all peripheral devices connected to the server. Turn off the server.
3.
Disconnect the AC power cord(s) from the server.