Intel SSR316MJ2 Product Specification - Page 39

Hard Disk Drive Bays

Page 39 highlights

Intel® Storage System SSR316MJ2 Chassis Peripheral Bays 4.1 Hard Disk Drive Bays The Storage System SSR316MJ2 chassis can support up to sixteen carrier-mounted SATA, 3.5" x 1", hard disk drives. The SATA drives may be "electrically" hot-swapped while the system power is applied, i.e., before or during POST. However, the SATA drives should NOT be hotswapped while the SAN Management application software is configured and active. See the Intel® Storage System SSR316MJ2 Software User Manual for more information. NOTE: 1) All drives must be populated in order, from left to right, in drive bay 0 thru drive bay 15. 2) Once a particular RAID configuration is applied to the present drives, if the drives are removed from the system for any reason, they will need to be re-installed in the exact same drive bays they were removed from. Please use the HDD labels provided in your Storage System SSR316MJ2 shipping container to number the drives 0 thru 15 prior to removal. 3) If a failed drive needs replacing, it must be replaced with the exact same manufacturer, model, and size. 4) For more information on configuring supported RAID levels, refer to the Intel® Storage System SSR316MJ2 Software User Manual available from Intel Business Link (IBL) or your Intel sales representative. Figure 12. Intel® Storage System SSR316MJ2 Hard Disk Drive Bays Revision 1.0 29 Intel Order number C75916-001

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

Intel® Storage System SSR316MJ2
Chassis Peripheral Bays
Revision 1.0
29
Intel Order number C75916-001
4.1
Hard Disk Drive Bays
The Storage System SSR316MJ2 chassis can support up to sixteen carrier-mounted SATA,
3.5” x 1”, hard disk drives. The SATA drives may be “electrically” hot-swapped while the system
power is applied, i.e., before or during POST. However, the SATA drives should NOT be hot-
swapped while the SAN Management application software is configured and active. See the
Intel® Storage System SSR316MJ2 Software User Manual for more information.
NOTE:
1)
All drives must be populated in order, from left to right, in drive bay 0 thru drive bay 15.
2)
Once a particular RAID configuration is applied to the present drives, if the drives are
removed from the system for any reason, they will need to be re-installed in the exact
same drive bays they were removed from. Please use the HDD labels provided in your
Storage System SSR316MJ2 shipping container to number the drives 0 thru 15 prior to
removal.
3)
If a failed drive needs replacing, it must be replaced with the exact same manufacturer,
model, and size.
4)
For more information on configuring supported RAID levels, refer to the
Intel
®
Storage
System SSR316MJ2 Software User Manual
available from Intel Business Link (IBL) or your
Intel sales representative.
Figure 12. Intel
®
Storage System SSR316MJ2 Hard Disk Drive Bays