JVC BR-DV6000U User Manual - Page 46

To use the SERIAL IN terminal, set REMOTE SEL SER

Page 46 highlights

RECORDING - Recording with serial remote terminals - Recording can be turned ON/OFF with a serial remote controller or foot switch connected to the SERIAL REMOTE IN terminal located at the rear panel of BR-DV6000. Mini MENU DISP RESET SEARCH- SET SEARCH+ MIC HOLD BLANK CUE UP PHONES REC LEVEL CH-1/3 CH-2/4 PROFESSIONAL BR-DV6000 OPERATE A.DUB REC PLAY PAUSE EJECT REW STOP FF AUDIO INPUT COUNTER MONITOR OUTPUT SELECT CTL L CH-1/2 DV TC MIX MIX LINE UB R CH-3/4 Y/C (CPN) REMOTE LOCAL REMOTE/LOCAL switch VIDEO LINE Y/C COMPONENT IN R-Y B-Y Y OUT REMOTE2 IN OUT AUDIO CH 1/3 CH 2/4 IN MONITOR OUT SIGNAL GND DC12V SYNC IN IN DV IN/OUT OUT TIME CODE IN OUT OFF REC PLAY SERIAL REMOTE TIMER OUT MONITOR OUT REMOTE1 SERIAL IN SERIAL OUT REMOTE (1/2) Menu screen ---R E MO T E [ 1 / 2 ] --- REMOT E S E L 9 P REMOT E S E L S ER REMOT E S E L DV REMOT E S E L J VC REMOT E S E L NE T LOCA L FUNCT I ON PREROL L NEXT PAGE PAGE BACK ON ON ON ON ON STP+EJT 7SEC Memo ● Besides recording, the serial remote controller can perform other functions. ● If the REMOTE SEL SER is set to ON, unit buttons that can be operated can be selected from LOCAL FUNCTION in the REMOTE (1/2) Menu screen. REMOTE (2/2) Menu screen ---R E M O T E [ 2 / 2 ] --- REM F F / REW MODE REM STOP SEL . PB START DELAY SYNCHRON I ZAT I ON CONTROL LER SEL FOOT SW PAGE BACK F F / REW EE OF ON TYPE1 OFF Serial IN terminal Foot switch Signal H L 400ms Min 46 :Connection: • Serial remote controller: RM-G30 • Foot switch The serial remote controller (RM-G30, sold separately) can be con- nected to the SERIAL REMOTE IN terminal located on the rear panel of BR-DV6000. The input signals of the SERIAL REMOTE IN terminal can be through- output from the SERIAL REMOTE OUT terminal. (Only with OPER- ATE ON) :Setting: Ⅵ To use the SERIAL IN terminal, set REMOTE SEL SER in the REMOTE (1/2) Menu screen to ON or LOC+REM. Then, set the REMOTE/LOCAL switch on the front panel accordingly. ● REMOTE SEL SER ON : When the REMOTE/LOCAL switch is set to REMOTE, operations can be performed via the SERIAL REMOTE IN terminal. LOC+REM: With the REMOTE/LOCAL switch is set either way, operations can be performed via the SERIAL REMOTE IN terminal.With this setting, the buttons and switches of the unit can be used too. Ⅵ Set FOOT SW in the REMOTE (2/2) Menu screen according to how the serial remote terminal is used. OFF : Set to OFF when the serial remote controller is used. The footswitch cannot be used. L EDGE : Recording and recording pause is switched at the LOW edge of the footswitch signal. H EDGE : Recording and recording pause is switched at the HIGH edge of the footswitch signal. L LEVEL : Recording is performed at the LOW edge and paused at the HIGH edge of the footswitch signal. :Operation: Before using the foot switch, set BR-DV6000 to the RECORDING or RECORDING PAUSE mode using the relevant buttons of the unit. (Only with L EDGE and H EDGE) Memo ● The foot switch can only be used to switch between RECORDING ON and OFF. ● The foot switch can be operated regardless of the setting of the REMOTE/LOCAL switch.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

46
BR-DV6000
PROFESSIONAL
MENU
RESET
A.DUB
EJECT
COUNTER
AUDIO
INPUT
SELECT
MONITOR
OUTPUT
REMOTE
LOCAL
CTL
L
MIX
R
CH-1/2
MIX
CH-3/4
DV
LINE
Y/C
(CPN)
TC
UB
REW
STOP
FF
REC
OPERATE
PLAY
PAUSE
DISP
SET
SEARCH+
BLANK
CUE UP
HOLD
PHONES
REC
LEVEL
CH-1/3
CH-2/4
MIC
SEARCH–
Mini
VIDEO
LINE
IN
OUT
MONITOR
OUT
DC12V
DV
IN/OUT
IN
OUT
OFF
AUDIO
REMOTE2
IN
B-Y
R-Y
SYNC IN
TIME CODE
IN
OUT
Y
COMPONENT
OUT
CH 1/3
CH 2/4
IN
OUT
MONITOR
OUT
REMOTE1
TIMER
REC
PLAY
SERIAL
REMOTE
SIGNAL
GND
Y/C
SERIAL OUT
SERIAL IN
———
R E MO T E [ 1 / 2 ]
———
REMOTE
SEL
9P
ON
REMOTE
SEL
SER
ON
REMOTE
SEL
DV
ON
REMOTE
SEL
JVC
ON
REMOTE
SEL
NET
ON
LOCAL
FUNCT I ON
STP+EJ T
PREROL L
7SEC
NEXT
PAGE
PAGE
BACK
———
R E MO T E [ 2 / 2 ]
———
REM
F F / R EW
MODE
F F / R EW
REM
STOP
SEL.
EE
PB
START
DELAY
OF
SYNCHRONIZATION
ON
CONTROLLER
SEL
TYPE1
FOOT
SW
OFF
PAGE
BACK
:
Connection
:
The serial remote controller (RM-G30, sold separately) can be con-
nected to the SERIAL REMOTE IN terminal located on the rear panel
of BR-DV6000.
The input signals of the SERIAL REMOTE IN terminal can be through-
output from the SERIAL REMOTE OUT terminal. (Only with OPER-
ATE ON)
:
Setting
:
±
To use the SERIAL IN terminal, set REMOTE SEL SER
in the REMOTE (1/2) Menu screen to ON or LOC+REM.
Then, set the REMOTE/LOCAL switch on the front panel
accordingly.
REMOTE SEL SER
ON
: When the REMOTE/LOCAL switch is set to REMOTE,
operations can be performed via the SERIAL REMOTE
IN terminal.
LOC+REM
: With the REMOTE/LOCAL switch is set either way,
operations can be performed via the SERIAL REMOTE
IN terminal. With this setting, the buttons and switches
of the unit can be used too.
±
Set FOOT SW in the REMOTE (2/2) Menu screen ac-
cording to how the serial remote terminal is used.
OFF
: Set to OFF when the serial remote controller is used.
The footswitch cannot be used.
L EDGE
: Recording and recording pause is switched at the LOW
edge of the footswitch signal.
H EDGE
: Recording and recording pause is switched at the
HIGH edge of the footswitch signal.
L LEVEL
: Recording is performed at the LOW edge and paused
at the HIGH edge of the footswitch signal.
:
Operation
:
Before using the foot switch, set BR-DV6000 to the RECORDING or
RECORDING PAUSE mode using the relevant buttons of the unit.
(Only with L EDGE and H EDGE)
Memo
The foot switch can only be used to switch between RECORDING
ON and OFF.
The foot switch can be operated regardless of the setting of the
REMOTE/LOCAL switch.
Memo
Besides recording, the
serial remote controller
can perform other func-
tions.
If the REMOTE SEL SER
is set to ON, unit buttons
that can be operated can
be selected from LOCAL
FUNCTION in the RE-
MOTE
(1/2)
Menu
screen.
Recording can be turned ON/OFF with a serial remote controller or foot switch connected to the
SERIAL REMOTE IN terminal located at the rear panel of BR-DV6000.
REMOTE/LOCAL switch
Serial remote controller: RM-G30
Foot switch
REMOTE (1/2) Menu screen
REMOTE (2/2) Menu screen
RECORDING
– Recording with serial remote terminals –
Foot switch
Serial IN
H
400ms
L
Min
Signal
terminal