JVC DLA-HD10KSU DLA-HD10K Owner's Manual (50 pages) - Page 38
Resetting Lamp Time
View all JVC DLA-HD10KSU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Replacing the Lamp (continued) Resetting Lamp Time After installing a new lamp (lamp unit), reset the lamp time. The lamp time counter will be reset and a new count will start. ● If the accumulated lamp time has reached 2000 hours, this unit will not work (lamp does not light up) unless the lamp time is reset. ON OPERATE OFF CHP LIGHT TEST MENU EXIT ENTER EXIT ENTER PRESET T ZOOM W HIDE HIDE K FOCUS a Insert plug into the power outlet ● The main power turns on and the [STAND BY] indicator on the unit lights up. b Press the [EXIT], [ENTER] and [HIDE] buttons sequentially, then press the [K] button for 2 seconds or more ● The [STAND BY] and [OPERATE] indicators will alternately blink for a duration of about 3 seconds each. After blinking stops, lamp time resets and the unit returns to the standby mode ([STAND BY] indicator lights up). EXIT ENTER Press as per normal HIDE Press for 2 seconds or more To ensure the lamp time has been reset The lamp time can be checked via the ALamp TimeB item of the AInformationB menu. (A Pages 28, 32) Caution During Reset Work Reset the lamp time only when you have replaced the lamp. Never reset it when the lamp is still in use. Otherwise, the approximate standard for gauging replacement time may be inaccurate, lamp performance may deteriorate and lamp blowout may occur. 38