JVC GY-HD250U 117 page operator's manual for the GY-HD250U - Page 52

Synchronizing with the, Time Code of the IEEE1394, DV-Connected Master Unit

Page 52 highlights

e_hd250.book Page 48 Tuesday, October 24, 2006 3:11 PM PREPARATIONS FOR OPERATION Synchronizing with the Time Code of the IEEE1394 (DV)-Connected Master Unit You can synchronize the time code when performing multi-camera recording. The internal time code generator will be synchronized with the time code in the signal input from the IEEE1394 terminal. After synchronization (slave lock), the internal time code generator continues to run even if the IEEE1394 cable is disconnected. Master unit Slave unit MACRO MACRO VF BRIGHT USER 1 USER 2 USER 3 ND FILTER 2 1 MENU STATUS WHT.BAL AUTO AUTO AUDIO CH-1 LEVEL CH-2 ON OFF POWER REC Slide the IEEE1394 switch to the [DV] side. IEEE1394 terminal IEEE1394 cable VF BRIGHT USER 1 USER 2 USER 3 ND FILTER 2 1 MENU STATUS WHT.BAL AUTO AUTO AUDIO CH-1 LEVEL CH-2 ON OFF POWER REC IEEE1394 terminal Slide the IEEE1394 switch to the [DV] side. You can use the GY-HD250U, GY-HD251E, GY-HD110U, or GY-HD111E as a slave unit. Connections Connect the master unit and the slave unit with an IEEE1394 cable. Settings and Operations • Master unit (GY-HD100U/GY-HD100E/GY-HD101E/GYHD110U/GY-HD110E/GY-HD111E/GY-HD250U/GYHD251E) 1. Set the IEEE1394 switch on the left side to [DV]. 2. Set to Camera mode. 3. Set the recording format to DV-60I or DV50I. 4. Set the TC GENE. switch to [FREE]. • Slave unit (GY-HD250U/GY-HD251E/GY-HD110U/GYHD111E) 1. Set the IEEE1394 switch on the left side to [DV]. 2. Set to VTR mode. 3. Check that the camera image from the master unit is input. 4. Set TCG SOURCE in the TC/UB/CLOCK menu screen to INTERNAL. (GY-HD250U, GY-HD251E) 5. Set the TC GENE. switch to [FREE] and the TC DISPLAY switch to [TC]. 6. Set to STOP mode or EJECT mode. 7. Press the STOP button for 1 second. • The DV input time code data from the IEEE1394 terminal is displayed in the status display. (When status is in magnified size, characters are displayed.) 8. Press the USER1 button to begin slave lock. (To skip slave lock, press the USER3 button and clear the status display.) Status display DTCG 00 : 00 : 00 : 00 TC SLAVE LOCK ? EXECUTE CANCEL USER1 USER3 9. Check that the time code that is synchronized with the master unit is running. 10.Disconnect the IEEE1394 cable. 11.The slave unit finally returns to Camera mode. MEMO „ Slave lock cannot be performed in the following instances. • Slave unit is in CAMERA mode • Slave unit is in VTR mode and there is no DV signal • The TC GENE. switch on the slave unit is not set to FREE • HDV format „ If slave lock is performed in DV format and is then switched to HDV format, frame digit may deviate. „ If power is turned off, slave lock is disabled. Perform slave lock operation again. „ Slave lock cannot be performed for UB (User's bit). „ If the frame rate for the master unit and slave unit is not synchronized, it will not run properly. Synchronize frame rate before using. „ If DROP/NON DROP is not synchronized, it will not run properly. Synchronize DROP/NON DROP before using. 48

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117

PREPARATIONS FOR OPERATION
48
Synchronizing with the
Time Code of the IEEE1394
(DV)-Connected Master Unit
You can synchronize the time code when performing multi-camera recording. The internal time code generator will be synchro-
nized with the time code in the signal input from the IEEE1394 terminal. After synchronization (slave lock), the internal time code
generator continues to run even if the IEEE1394 cable is disconnected.
You can use the GY-HD250U, GY-HD251E, GY-HD110U, or
GY-HD111E as a slave unit.
Connections
Connect the master unit and the slave unit with an IEEE1394
cable.
Settings and Operations
Master unit (GY-HD100U/GY-HD100E/GY-HD101E/GY-
HD110U/GY-HD110E/GY-HD111E/GY-HD250U/GY-
HD251E)
1.
Set the IEEE1394 switch on the left side to [DV].
2.
Set to Camera mode.
3.
Set the recording format to DV-60I or DV50I.
4.
Set the TC GENE. switch to [FREE].
Slave unit (GY-HD250U/GY-HD251E/GY-HD110U/GY-
HD111E)
1.
Set the IEEE1394 switch on the left side to [DV].
2.
Set to VTR mode.
3.
Check that the camera image from the master unit is input.
4.
Set TCG SOURCE in the TC/UB/CLOCK menu screen to
INTERNAL. (GY-HD250U, GY-HD251E)
5.
Set the TC GENE. switch to [FREE] and the TC DISPLAY
switch to [TC].
6.
Set to STOP mode or EJECT mode.
7.
Press the STOP button for 1 second.
The DV input time code data from the IEEE1394 termi-
nal is displayed in the status display. (When status is in
magnified size, characters are displayed.)
8.
Press the USER1 button to begin slave lock.
(To skip slave lock, press the USER3 button and clear
the status display.)
9.
Check that the time code that is synchronized with the
master unit is running.
10.
Disconnect the IEEE1394 cable.
11.
The slave unit finally returns to Camera mode.
MEMO
Slave lock cannot be performed in the following
instances.
Slave unit is in CAMERA mode
Slave unit is in VTR mode and there is no DV signal
The TC GENE. switch on the slave unit is not set to
FREE
HDV format
If slave lock is performed in DV format and is then
switched to HDV format, frame digit may deviate.
If power is turned off, slave lock is disabled. Perform
slave lock operation again.
Slave lock cannot be performed for UB (User’s bit).
If the frame rate for the master unit and slave unit is not
synchronized, it will not run properly. Synchronize frame
rate before using.
If DROP/NON DROP is not synchronized, it will not run
properly. Synchronize DROP/NON DROP before using.
MACRO
USER 3
USER 2
USER 1
STATUS
MENU
2
1
ND FILTER
REC
OFF
ON
POWER
WHT.BAL
VF BRIGHT
MACRO
USER 3
USER 2
USER 1
STATUS
MENU
2
1
ND FILTER
REC
OFF
ON
POWER
WHT.BAL
VF BRIGHT
Master unit
Slave unit
IEEE1394 cable
IEEE1394 terminal
IEEE1394 terminal
Slide
the
IEEE1394
switch to the [DV] side.
Slide
the
IEEE1394
switch to the [DV] side.
DTCG
TC
SLAVE
LOCK
?
EXECUTE
USER1
00 : 00 : 00 : 00
CANCEL
USER3
Status display
e_hd250.book
Page 48
Tuesday, October 24, 2006
3:11 PM