Connecting RM-P210 Notes to be taken when operating RM-P210 When using RM-P210 menu to carry out the setting of KY-F560, some items of RM-P210 menu setting may not be consistent with the operations of KY-F560. RM-P210 Menu Operation of KY-F560 No Item Variable Value 4G Ⅵ "PROCESS" screen "KNEE POINT" (KNEE POINT setting when AUTO KNEE is off) ~~ ~ ~ 10 NORMAL -10 KNEE point may vary as follows: NORMAL : 100 % (Maximum level) -10 : 80 % (Minimum level) Level will change by 5 % with every 2-step adjustment on the minus side. Setting the plus side (1 to 10) will not change the KNEE point. 4K "GAMMA LEVEL" (GAMMA CURVE Correction) ~~ 10 NORMAL -10 Level will change (switch to next level) with every 2-step adjustment. (-5 ~NORMAL ~5) 5B Ⅵ "OPERATION" screen "V. GAIN STEP" (VARIABLE GAIN STEP SETTING) 0.1 dB 1.0 dB With 0.1 dB setting, turning of RMP210 [VARIABLE GAIN] knob will cause the gain level to change at 0.2 dB step. With 1.0 dB setting, gain level will change at 1.0 dB step. 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

20
Notes to be taken when operating RM-P210
When using RM-P210 menu to carry out the setting of KY-F560, some items of RM-P210
menu setting may not be consistent with the operations of KY-F560.
RM-P210 Menu
Connecting RM-P210
Operation of KY-F560
No
4G
4K
5B
Item
±
“PROCESS”
screen
“KNEE POINT”
(KNEE POINT setting
when AUTO KNEE is
off)
“GAMMA LEVEL”
(GAMMA
CURVE
Correction)
±
“OPERATION”
screen
“V. GAIN STEP”
(VARIABLE GAIN
STEP SETTING)
KNEE point may vary as follows:
NORMAL : 100 % (Maximum level)
–10
: 80 % (Minimum level)
Level will change by 5 % with every
2-step adjustment on the minus side.
Setting the plus side (1 to 10) will not
change the KNEE point.
Level will change (switch to next level)
with every 2-step adjustment.
(–5 ~NORMAL ~5)
With 0.1 dB setting, turning of RM-
P210 [VARIABLE GAIN] knob will
cause the gain level to change at 0.2
dB step.
With 1.0 dB setting, gain level will
change at 1.0 dB step.
~
~
Variable Value
10
NORMAL
–10
10
NORMAL
–10
0.1 dB
1.0 dB
~
~
~
~