Other Settings [Program version] The version of the VN-C2WU main unit firmware. Cannot be changed. [Power Frequency] This setting reduces the amount of flicker under fluorescent lighting. Set to 50Hz or 60Hz in accordance with the power frequency at the installation location. [Password] Specify using up to 8 letters. Enter (re-enter) the same password two times in each level for confirmation purposes. [Auto Refresh] Specify Pan/Tilt position display in the (Control page) and (Configration page) is automatically refreshed or not. Password function An access protection using a password is provided to regulate connecting PCs (users) connected to the VN-C2WU. This access protection function has three levels to match the access levels. The pages that can be accessed at each of these levels are as shown below. (Refer to page 22 for the VN-C2WU web page configuration.) Password level Accessible page User level Still Image page and Live Image page. Operator level The above pages and (Pan/Tilt) control page. Administrator level The above pages and Settings page. Caution Never forget the current password because the password setting cannot be changed unless it matches the Administrator level password. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

11
Other Settings
[Program version]
The version of the VN-C2WU main unit firmware.
Cannot be changed.
[Power Frequency]
This setting reduces the amount of flicker under fluorescent lighting. Set to 50Hz or 60Hz in
accordance with the power frequency at the installation location.
[Password]
Specify using up to 8 letters. Enter (re-enter) the same password two times in each level for
confirmation purposes.
[Auto Refresh]
Specify Pan/Tilt position display in the (Control page) and (Configration page) is automatically
refreshed or not.
Password function
An access protection using a password is provided to regulate connecting PCs (users) connected to
the VN-C2WU. This access protection function has three levels to match the access levels. The pages
that can be accessed at each of these levels are as shown below.
(Refer to page 22 for the VN-C2WU web page configuration.)
Password level
User level
Operator level
Administrator level
Accessible page
Still Image page and Live Image page.
The above pages and (Pan/Tilt) control page.
The above pages and Settings page.
Never forget the current password because the password setting cannot be
changed unless it matches the Administrator level password.