Jenn-Air JGRP436HL Installation Instructions - Page 6
Location Requirements
View all Jenn-Air JGRP436HL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Location Requirements IMPORTANT: Observe all governing codes and ordinances. Do not obstruct flow of combustion and ventilation air. Product Dimensions ■ It is the installer's responsibility to comply with installation clearances specified on the model/serial/rating plate. The model/serial/rating plate is located under the console on the right-hand side. NOTE: Cooktop features may differ. 30" (76.2 cm) models ■ It is recommended that a 585 CFM (993.9 m3/hr) or larger A range hood be installed above the range. ■ Follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface. ■ Recessed installations must provide complete enclosure of the sides and rear of the range. ■ All openings in the wall or floor where range is to be installed must be sealed. ■ Do not seal the range to the side cabinets. ■ Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances. B ■ The anti-tip bracket must be installed. To install the anti-tip bracket shipped with the range, see the "Install Anti-Tip Bracket" section. D ■ Grounded electrical supply is required. See the "Electrical Requirements" section. ■ Proper gas supply connection must be available. See the "Gas Supply Requirements" section. ■ Contact a qualified floor covering installer to check that the floor covering can withstand at least 200°F (93°C). Use an insulated pad or 1/4" (6.4 cm) plywood over carpet and under range if installing range over carpeting. IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate, or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C). Mobile Home - Additional Installation Requirements The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or local codes. In Canada, the installation of this cooktop must conform with the current standards CAN/CSA-A240-latest edition or with local codes. C A. 273/4" (70.5 cm) depth with control panel (See NOTE.) B. 353/4" (90.8 cm) range height when sitting on the wheels C. 297/8 " (75.7 cm) width D. Model/serial/rating plate location/SAID label 36" (91.4 cm) models A Mobile Home Installations Require: ■ When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing B the range is adequate as long as it conforms to the standards listed above. D C A. 271⁄8" (68.9 cm) depth with control panel (See NOTE.) B. 353⁄4" (90.8 cm) range height when sitting on the wheels C. 36" (91.4 cm) width D. Model/serial/rating plate location/SAID label 6