To Adjust, Timing, Of The, Needle, Upper, Knife
View all Kenmore 16677 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
TO ADJUST THE TIMING OF THE NEEDLE AND THE UPPER KNIFE CORRECT SETTING: THE UPPER KNIFE TIMING IS THE SAME AS THAT OFTHE NEEDLE BAR. THE UPPER KNIFE SHOULD BE ALSO AT ITS HIGHEST POSITION WHEN THE NEEDLE BAR IS AT HIGHEST POSITION. TO ADJUST: 1.REMOVE THE BACK COVER UNIT. 2.LOOSEN TWO SETSCREWS (A), AND MOVE THE BALANCE WEIGHT TO LEFT. 3.LOOSEN TWO SETSCREWS (B), AND ADJUST THE NEEDLE AND UPPER KNIFE TIMING. # TURN THE UPPER KNIFE DRIVE CAM TO THE DIRECTION (C) WHEN THE UPPER KNIFE TIMING IS DELAYED. # TURN THE UPPER KNIFE DRIVE CAM TO THE DIRECTION (D) WHEN THE UPPER KNIFE TIMING IS TOO SOON. 4.TIGHTEN TWO SETSCREWS (B) FIRMLY. MOVE THE BALANCE WEIGHT TO RIGHT. MATCH THE GUIDE LINE ON THE BALANCE WEIGHT WITH THE ONE ON THE MAIN SHAFT CORRECTLY. THEN TIGHTEN THE TWO SCREWS (A). 5. TURN THE HANDWHEEL TOWARD YOU ONE CYCLE, AND RECHECK THE NEEDLE AND THE UPPER KNIFE TIMING. 6. ATTACH THE BACK COVER UNIT. WHEN THE NEEDLE BAR GOES UP, THE UPPER KNIFE GOES UP. WHEN THE NEEDLE BAR GOES DOWN, THE UPPER KNIFE ALSO GOES DOWN. @0 UPPER KNIFE DRIVE CAM GUIDE LINE ON MAIN SHAFT \ DIRECTION (D) --(£_ ..... DIRECTIO (C_) SETSCREW(B) SETSCREW (A) 12