Kenmore 16677 Service Manual - Page 17
To Adjust, The Clearance, Between
View all Kenmore 16677 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
TO ADJUST THE CLEARANCE BETWEEN THE NEEDLES ANDTHE LOWER LOOPER/NEEDLE GUARDS (2 of 3) CORRECT SETTING: THE STANDARD CLEARANCE BETWEEN THE RIGHT NEEDLE AND THE TIP OFTHE LOWER LOOPER SHOULD BE OTO 0.1 MM. TO ADJUST: 1. REMOVE THE LEFT NEEDLE ONLY, 2, TURN THE HANDWEEL TOWARDS YOU TO BRING THE TIP OF THE LOWER LOOPER FROM THE LEFT HAND TO THE REAR SIDE OF THE RIGHT NEEDLE. 3. LOOSEN THE HEXAGONAL SOCKET SCREWS (A) ON THE FRONT NEEDLE GUARD. OPEN A SPACE BETWEEN THE FRONT NEEDLE GUARD AND THE NEEDLE. 4. LOOSEN THE HEXAGONAL BOLT (B). ADJUST THE CLEARANCE BETWEEN THE RIGHT NEEDLE AND THE TIP OF THE LOWER LOOPER TO BE 0 MM TO 0.1 MM BY SLIDING THE LOWER LOOPER UNIT TO THE FRONT OR BACK.TIGHTEN THE HEXAGONAL BOLT B. REAR NEEDLE GUARD 7 1 ,_ ,_ IIp'L FGR_NTNEEDLE _/_,_ HEXAGONAL SCERWS (A) . zz SOCKET HEXAGONAL BOLT (B)_ _ )_ LOWER LOOPER BACE NEEDLE #11 _-x_ It_ 0 TO 0.1 MM LOWER LOOPER REAR NEEDLE GUARD 15