Kenmore 33968 Owners Manual - Page 5

In This, Manual, installation, instructions, ENTIRE, MANUAL, RECOVERY, DIMENSIONS, GALS., MINIMUM,

Page 5 highlights

Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-8O0-4-MY-HOME% They will arrange for prompt, quality installation by Sears authorized contractors. Abbreviations Found In This Instruction Manual: CSA - Canadian Standards Association ANSI -American National Standards institute NFPA - National Fire Protection Association ASME -American Society of Mechanical Engineers GAMA - Gas Appliance Manufacturers Association This gas-fired water heater is design certified by CSA INTERNATIONAL under American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition). Read the "Safety Precautions" section, page 3 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE. This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER. • The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the following: In the United States: The National Fuel Gas Code ANSI Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd, Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269. If after reading this manual you have any questions or do not understand any portion of the instructions, call the Sears Service Center. Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. See figure 1. Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual. For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814. Massachusetts in accordance Code requires this water heater to be installed with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00. Complies with SCAQMD rule #1121 and districts equivalent NOx requirements. having MODEL NUMBERS 153.339382 153.339282 153.339482 153.339982 153.339161 153.339562 153.339762 153.339640 153.339680 TANK CAPACITY IN GALS (LTRS) TYPE OF GAS INPUT RATE (Btu/hr) RECOVERY RATE GALS. PER HOUR @ 90 ° F RISE MINIMUM VENT PIPE iNCHES (ram) DIAMETER INCHES (rnm) DIMENSIONS iN INCHES (turn) HEIGHT TO JACKET TOP 30 (114) 40 (151) 40 (151) 40 (151) 50 (189) 50 (189) 48 (182) 65 (246) 65 (246) NATURAL NATURAL NATURAL PROPANE NATURAL NATURAL NATURAL NATURAL NATURAL 40,000 40,000 40,000 37,000 40,000 40,000 50,000 40,000 65,000 41.5 40.9 39.9 36.9 42.0 40.9 51.2 40.0 67.0 5 3" (76) or 4" (102) I6" (406) 3" (76) or 4" (102) 20" (508) 3" (76) or 4" (102) I8 1/2" (470) 3" (76) or 4" (102) I8 1/2" (470) 3" (76) or 4" (102) 24" (810) 3" (76) or 4" (102) 20" (508) 4" (102) 20" (508) 3" (76) or 4" (102) 22" (559) 4" (102) 24" (610) 57 I/2" (I ,46I) 47 I/4" (I ,200) 55 I/2" (I ,410) 55 I/2" (I ,410) 48 3/4" (1,238) 56 I/2" (1,435) 56 I/2" (1,435) 60 I/4" (1,530) 60 I/4" (1,530)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

Thank
You
for
purchasing
a
Kenmore
water
heater.
Properly
installed
and
maintained,
it should
give
you years
of trouble
free
service.
If you
should
decide
that
you want
the
new
water
heater
professionally
installed
by Sears
call
1-8O0-4-MY-HOME%
They
will
arrange
for
prompt,
quality
installation
by Sears
authorized
contractors.
Abbreviations
Found
In This
Instruction
Manual:
CSA
- Canadian
Standards
Association
ANSI
-American
National
Standards
institute
NFPA
- National
Fire
Protection
Association
ASME
-American
Society
of Mechanical
Engineers
GAMA
- Gas
Appliance
Manufacturers
Association
This
gas-fired
water
heater
is
design
certified
by
CSA
INTERNATIONAL
under
American
National
Standard/CSA
Standard
for
Gas
Water
Heaters
ANSI
Z21.10.1
• CSA
4.1
(current
edition).
Read
the
"Safety
Precautions"
section,
page
3 of this
manual
first
and
then
the
entire
manual
carefully.
If you
don't
follow
the
safety
rules,
the
water
heater
will
not
operate
properly.
It
could
cause
DEATH,
SERIOUS
BODILY
INJURY
AND/OR
PROPERTY
DAMAGE.
This manual
contains
instructions
for the
installation,
operation,
and
maintenance
of the
gas-fired
water
heater.
It also
contains
warnings
through
out
the
manual
that
you
must
read
and
be
aware
of. All warnings
and
all
instructions
are essential
to the
proper
operation
of the
water
heater
and
your
safety.
Since
we
cannot
put
everything
on the
first
few
pages,
READ
THE
ENTIRE
MANUAL
BEFORE
ATTEMPTING
TO
INSTALL
OR
OPERATE
THE
WATER
HEATER.
The
installation
must
conform
with
these
instructions
and
the
local
code
authority
having
jurisdiction.
In the
absence
of local
codes,
installations
shall
comply
with
the
following:
In
the
United
States:
The
National
Fuel
Gas
Code
ANSI
Z223.1/NFPA
54.
This
publication
is
available
from
the
Canadian
Standards
Association,
8501
East
Pleasant
Valley
Rd,
Cleveland
Ohio
44131,
or The
National
Fire
Protection
Association,
1 Batterymarch
Park,
Quincy,
MA 02269.
If
after
reading
this
manual
you
have
any
questions
or
do
not
understand
any
portion
of the
instructions,
call
the
Sears
Service
Center.
Carefully
plan
the
place
where
you
are
going
to
put
the
water
heater.
Correct
combustion,
vent
action,
and
vent
pipe
installation
are
very
important
in
preventing
death
from
possible
carbon
monoxide
poisoning
and
fires.
See
figure
1.
Examine
the
location
to
ensure
the
water
heater
complies
with
the
Facts
to Consider
About
the
Location
section
in this
manual.
For
California
installation
this
water
heater
must
be
braced,
anchored,
or
strapped
to
avoid
falling
or
moving
during
an
earthquake.
See
instructions
for
correct
installation
procedures.
Instructions
may
be
obtained
from
your
local
dealer,
wholesaler,
public
utilities
or California
Office
of the
State
Architect,
400
P Street,
Sacramento,
CA 95814.
Massachusetts
Code
requires
this water
heater
to be installed
in
accordance
with
Massachusetts
248-CMR
2.00:
State
Plumbing
Code
and
248-CMR
5.00.
Complies
with
SCAQMD
rule
#1121
and
districts
having
equivalent
NOx
requirements.
RECOVERY
DIMENSIONS
iN
TANK
RATE
GALS.
MINIMUM
VENT
INCHES
(turn)
MODEL
CAPACITY
IN
INPUT
RATE
PER HOUR
@
PIPE
iNCHES
DIAMETER
HEIGHT
TO
NUMBERS
GALS
(LTRS)
TYPE
OF
GAS
(Btu/hr)
90 °
F
RISE
(ram)
INCHES
(rnm)
JACKET
TOP
153.339382
30 (114)
NATURAL
40,000
41.5
3" (76) or 4" (102)
I6" (406)
57 I/2"
(I ,46I)
153.339282
40 (151)
NATURAL
40,000
40.9
3" (76) or 4" (102)
20" (508)
47 I/4"
(I ,200)
153.339482
40 (151)
NATURAL
40,000
39.9
3" (76) or 4" (102)
I8
1/2" (470)
55 I/2"
(I ,410)
153.339982
40 (151)
PROPANE
37,000
36.9
3" (76) or 4" (102)
I8
1/2" (470)
55 I/2"
(I ,410)
153.339161
50 (189)
NATURAL
40,000
42.0
3" (76) or 4" (102)
24" (810)
48 3/4" (1,238)
153.339562
50 (189)
NATURAL
40,000
40.9
3" (76) or 4" (102)
20" (508)
56 I/2"
(1,435)
153.339762
48 (182)
NATURAL
50,000
51.2
4" (102)
20" (508)
56 I/2"
(1,435)
153.339640
65 (246)
NATURAL
40,000
40.0
3" (76) or 4" (102)
22" (559)
60 I/4"
(1,530)
153.339680
65 (246)
NATURAL
65,000
67.0
4" (102)
24" (610)
60 I/4"
(1,530)
5