INSTALLATION INSTRUCTIONS Outdoor Side Burner Installation WARNING Excessive Weight Hazard 3. Using a wrench to tighten, connect the gas supply to the side burner. Use pipe-joint compound on all non-flared male threads. Do not kink or damage the flexible connector when moving the side burner. Use two or more people to move and install side burner. A Failure to do so can result in back or other injury. ■ Unpack side burner. Remove all packaging materials and remove side burner from carton. B ■ Move side burner close to desired outdoor location. Make Gas Connection Natural Gas Use This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with either the National Fuel Gas Code ANSI Z223.1 - latest edition, or CAN/CGA-B149.1 Natural Gas and Propane installation code. 1. Place side burner into outdoor enclosure, but leave enough room in back to connect to gas supply and plug in electrical single-prong plug to the side burner. WARNING D C A. ½" side burner gas pipe B. New CSA International approved "outdoor" flexible gas supply line C. Rear of side burner D. To Natural gas supply 4. Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe. A B Explosion Hazard Use a new CSA International approved "outdoor" gas supply line. Securely tighten all gas connections. Failure to do so can result in death, explosion, or fire. 2. A combination of pipe fittings must be used to connect the side burner to the existing gas line. If local codes permit, use an outdoor flexible stainless steel tubing gas connector, design-certified by CSA International, to connect the side burner to the rigid gas supply line. A ⁵⁄₈" diameter line is recommended. Pipe-joint compounds suitable for use with Natural gas must be used. Do not use TEFLON®† tape. A. Closed valve B. Open valve 5. Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found. †®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

11
INSTALLATION INSTRUCTIONS
Outdoor Side Burner Installation
Unpack side burner. Remove all packaging materials and
remove side burner from carton.
Move side burner close to desired outdoor location.
Make Gas Connection
Natural Gas Use
This installation must conform with local codes and ordinances.
In the absence of local codes, installations must conform with
either the National Fuel Gas Code ANSI Z223.1 - latest edition, or
CAN/CGA-B149.1 Natural Gas and Propane installation code.
1.
Place side burner into outdoor enclosure, but leave enough
room in back to connect to gas supply and plug in electrical
single-prong plug to the side burner.
2.
A combination of pipe fittings must be used to connect the
side burner to the existing gas line. If local codes permit, use
an outdoor flexible stainless steel tubing gas connector,
design-certified by CSA International, to connect the side
burner to the rigid gas supply line. A
⁵⁄₈
" diameter line is
recommended.
Pipe-joint compounds suitable for use with Natural gas must
be used. Do not use TEFLON
®†
tape.
3.
Using a wrench to tighten, connect the gas supply to the side
burner. Use pipe-joint compound on all non-flared male
threads. Do not kink or damage the flexible connector when
moving the side burner.
4.
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
5.
Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
WARNING
Excessive Weight Hazard
Use two or more people to move and install side
burner.
Failure to do so can result in back or other injury.
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor”
gas supply line.
Securely tighten all gas connections.
Failure to do so can result in death, explosion, or fire.
†®TEFLON
is a registered trademark of E.I. Du Pont De Nemours and Company.
A. ½" side burner gas pipe
B. New CSA International approved
“outdoor” flexible gas supply line
C. Rear of side burner
D. To Natural gas supply
A. Closed valve
B. Open valve
A
B
C
D
A
B