Wire Cable from Home Power Supply
![]() |
View all KitchenAid KODC504PPS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
4-Wire Cable from Home Power Supply IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding through neutral, New Branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction, and in Canada. Single Oven A B E F G 1. Connect the 2 black wires (B) together using a UL listed wire connector. 2. Connect the 2 red wires (C) together using a UL listed wire connector. 3. Untwist white wire from green (or bare) ground wire coming from the oven. 4. Connect the 2 white wires (F) together using a UL listed wire connector. 5. Connect the green (or bare) ground wire (H) from the oven cable to the green (or bare) ground wire (in the junction box) using a UL listed wire connector. 6. Install junction box cover. H C I D Double Oven A B E F G D C D A. Cable from home power supply B. Black wires C. Red wires D. 4-wire flexible conduit from oven E. Junction box H I F. White wires G. UL listed wire connectors H. Green (or bare) ground wires I. UL listed or CSA approved conduit connector 9
![](/manual_guide/products/kitchenaid-kosc504pps-installation-instructions-ac31d9c/9.png)