KitchenAid KVIB606DBS Installation Guide - Page 9

Warning

Page 9 highlights

Make Electrical Connection WARNING 6. Use UL listed wire connectors and connect white wires (E) together. WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Disconnect power. 2. Remove terminal box cover. 3. Remove the knockout in the terminal box, and then install a UL listed or CSA approved ¹⁄₂" (12.7 mm) strain relief. AB C A. Knockout B. Terminal box C. Terminal box cover 4. Run home power supply cable through strain relief and into the terminal box. A B C D Electrical Shock Hazard Electrically ground blower. Connect ground wire to green and yellow ground wire in terminal box. Failure to do so can result in death or electrical shock. 7. Connect green (or bare) ground wire from home power supply to yellow-green ground wire (F) in terminal box using UL listed wire connectors. 8. Tighten strain relief screw. 9. Install terminal box cover. 10. Check that all light bulbs are secure in their sockets. 11. Reconnect power. Optional Power Cord Kit Installations For optional power cord kit installations, follow the instructions supplied with the power cord kit. See the "Assistance or Service" section for information on ordering. NOTE: Use only with range hood cord connection kits that have been investigated and found acceptable for use with this model range hood. Install Duct Covers NOTE: Remove the film from the duct covers. 1. Assemble the upper duct covers together, and then install the duct covers around the support frame. The larger hole in the flanges of the upper duct cover must be outside the smaller hole in the mating flange of the other upper duct cover. 2. Secure the upper duct covers together with two 3.5 x 6.5 mm screws at the top and two 2.9 x 3 mm screws at the bottom. Install 1 screw on each side at the top and bottom of the assembled duct covers. A B E A. Home power supply cable B. UL listed or CSA approved strain relief C. Black wires F D. UL listed wire connectors E. White wires F. Green (or bare) and yellow- green ground wires 5. Use UL listed wire connectors and connect black wires (C) together. C A C A. 3.5 x 6.5 mm screws (2) B. Assembly holes (larger hole outside of smaller hole on both sides) C. 2.9 x 3 mm screws (2) 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

9
Make Electrical Connection
1.
Disconnect power.
2.
Remove terminal box cover.
3.
Remove the knockout in the terminal box, and then install a
UL listed or CSA approved
¹⁄₂
" (12.7 mm) strain relief.
4.
Run home power supply cable through strain relief and into
the terminal box.
5.
Use UL listed wire connectors and connect black wires (C)
together.
6.
Use UL listed wire connectors and connect white wires (E)
together.
7.
Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
8.
Tighten strain relief screw.
9.
Install terminal box cover.
10.
Check that all light bulbs are secure in their sockets.
11.
Reconnect power.
Optional Power Cord Kit Installations
For optional power cord kit installations, follow the instructions
supplied with the power cord kit. See the “Assistance or Service”
section for information on ordering.
NOTE:
Use only with range hood cord connection kits that have
been investigated and found acceptable for use with this model
range hood.
Install Duct Covers
NOTE:
Remove the film from the duct covers.
1.
Assemble the upper duct covers together, and then install the
duct covers around the support frame. The larger hole in the
flanges of the upper duct cover must be outside the smaller
hole in the mating flange of the other upper duct cover.
2.
Secure the upper duct covers together with two 3.5 x 6.5 mm
screws at the top and two 2.9 x 3 mm screws at the bottom.
Install 1 screw on each side at the top and bottom of the
assembled duct covers.
A. Knockout
B. Terminal box
C. Terminal box cover
A. Home power supply cable
B. UL listed or CSA approved
strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-
green ground wires
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
C
B
A
B
C
D
E
F
A. 3.5 x 6.5 mm screws (2)
B. Assembly holes (larger hole outside of
smaller hole on both sides)
C. 2.9 x 3 mm screws (2)
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A
A
B
C
C