KitchenAid KVIB606DSS Use & Care Guide - Page 16

Wiring Diagram

Page 16 highlights

SE11SA Junction box N L Gnd WIRING DIAGRAM IR switch Switch Position ON OFF Switch operation Connection 1 2 No connection Action Light ON Light OFF Y-G WW W BU RR BK W IR lamps BK BK BU R R W R BR Closure temperature: Temperature sensor 167˚F±5.4˚F (75+/-3˚C) Opening temperature: ≥140˚F (60˚C) W Y BK W W Y BU Y BU 7 5 3 1 Fan speed 8642 7 5 3 1 Fan speed 8 6 4 2 R GY W R GY R R W R BK BR 5 On 3 Off 1 Fan 6 4 2 R BK BR BU 5 On 3 Off 1 Fan 6 4 2 7 2 5 1 3 Off 1 Light 8 6 4 2 Y W GY BK Speed 1 Speed 2 Speed 3 BU 1 234 56 25uF 25uF 1 2 3 4 5 6 7 8 9 10 Y-G W R BK BU BR GY GY BR BR 1 23456 Y/G W R BK BU Y Y BR Y W Lamps Optional lamp used in 48" (121.9 cm) size hood Optional kit with 1 motor Motor Resistance (Ohms) Motor Characteristics Blue-Red: 18 Blue-White: 21.6 (min.) Blue-Black: 9.8 (max) Power supply: 120 VAC Power absorption: 420 W Blue-Gray: 14.3 Room Temp: 73.4˚F (23˚C) Frequency: 60 Hz Current: 3.7A Switch operation with button "1-2-3" Position 1 2 3 Connection 4 2 4 6 5 7 Action Speed 1 Speed 2 Speed 3 Switch operation with button "ON-OFF" Position ON OFF Connection 4 6 4 2 Action Motor ON Motor OFF Switch operation with button "Light" Position OFF Connection 4 2 Action Lights Off 1 46 Low Intensity 2 57 68 High Intensity 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

16
WIRING DIAGRAM
Junction box
N
L Gnd
Y-G
IR switch
Switch
W
BK
R
BR
Temperature
sensor
Closure
temperature:
167˚F±5.4˚F
(75+/-3˚C)
Opening
temperature:
140˚F (60˚C)
W
W
W
Y
BU
Y
BU
Y
1
2
4
3
6
5
W
Y
Lamps
Motor Resistance (Ohms)
Blue-Red: 18
Blue-Gray: 14.3
Blue-White: 21.6 (min.)
Room Temp: 73.4˚F (23˚C)
Blue-Black: 9.8 (max)
Switch operation with button “1-2-3”
Position
Connection
Action
1
2
4
3
6
5
2
4
7
Speed 1
Speed 2
Speed 3
Switch operation with button
ON-OFF”
Position
Connection
Action
4
6
2
4
Motor ON
Motor OFF
ON
OFF
Position
Connection
Action
Switch operation with button “Light”
1
2
OFF
6
4
2
4
7
6
8
5
Lights Off
Low
Intensity
High
Intensity
Motor Characteristics
Power supply: 120 VAC
Frequency: 60 Hz
Power absorption: 420 W
Current: 3.7A
Optional kit with 1 motor
BR
BR
Y
Y
BU
GY
BK
R
W
Y/G
1
2
4
3
6
7
5
8
9
10
25uF
BR
BR
25uF
BU
BK
GY
R
W
Y-G
1
2
4
3
6
5
Speed 1
Speed 2
Speed 3
BU
BK
GY
W
W
W
W
BU
R
W
R
R
R
R
GY
1
2
4
3
6
7
5
8
Fan speed
1
2
4
3
6
7
5
8
Fan speed
GY
R
W
R
R
BK
BR
On
Off
1
2
4
3
6
5
Fan
R
BK
BR
On
Off
Fan
1
2
4
3
6
5
BU
BK
Y
BU
BK
1
2
4
3
6
7
5
8
Off
1
2
Position
Connection
Action
1
2
W
BK
IR lamps
Switch
operation
ON
OFF
Light ON
Light OFF
No
connection
R
Light
Optional
lamp used
in 48" (121.9 cm)
size hood