KitchenAid KVIB606DSS Use & Care Guide - Page 5

Venting Requirements - installation

Page 5 highlights

Installation Dimensions 36" (91.4 cm) or 48" (121.9 cm) or cabinet opening width (if installed between cabinets) 18" (45.7 cm) min. clearance upper cabinet to countertop See Note* X* 36" (91.4 cm) countertop height IMPORTANT: Minimum distance "X": 24" (61 cm) from electric cooking surfaces Minimum distance "X": 30" (76.2 cm) from gas cooking surfaces The chimneys can be adjusted for different ceiling heights. See the following chart. Vented Installations Min. ceiling height Max. ceiling height Electric cooking surface 7' 9" (2.36 m) 10' 2" (3.1 m) Gas cooking surface 8' 3" (2.51 m) 10' 2" (3.1 m) *NOTE: The range hood chimneys are adjustable and designed to meet varying ceiling or soffit heights depending on the distance "X" between the bottom of the range hood and the cooking surface. For higher ceilings, an Extension Kit Part Number W10352733 is available from your dealer or an authorized parts distributor. The chimney extension replaces the chimney shipped with the range hood. Venting Requirements ■ Vent system must terminate to the outdoors. ■ Do not terminate the vent system in an attic or other enclosed area. ■ Do not use 4" (10.2 cm) laundry-type wall caps. ■ Use metal vent only. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended. ■ The length of vent system and number of elbows should be kept to a minimum to provide efficient performance. For the Most Efficient and Quiet Operation: ■ Use no more than three 90° elbows. ■ Make sure there is a minimum of 24" (61.0 cm) of straight vent between the elbows if more than 1 elbow is used. ■ Do not install 2 elbows together. ■ Use clamps to seal all joints in the vent system. ■ The vent system must have a damper. If the roof or wall cap has a damper, do not use the damper supplied with the range hood. ■ Use caulking to seal exterior wall or roof opening around the cap. ■ The size of the vent should be uniform. Cold Weather Installations An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the vent system enters the heated portion of the house. Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area. Venting Methods Typical Internal Blower Motor System Venting Installations A 10" (25.4 cm) round vent system is needed for installation (not included). The range hood exhaust opening is 10" (25.4 cm) round. NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance. Vent system can terminate either through the roof or wall. To vent through the wall, a 90º elbow is needed. Roof Venting Wall Venting A B B A A. Roof cap B. 10" (25.4 cm) round vent A. Wall cap B. 10" (25.4 cm) round vent 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

5
Installation Dimensions
IMPORTANT:
Minimum distance “X”: 24" (61 cm) from electric cooking
surfaces
Minimum distance “X”: 30" (76.2 cm) from gas cooking
surfaces
The chimneys can be adjusted for different ceiling heights. See
the following chart.
*NOTE:
The range hood chimneys are adjustable and designed
to meet varying ceiling or soffit heights depending on the
distance “X” between the bottom of the range hood and the
cooking surface. For higher ceilings, an Extension Kit Part
Number W10352733 is available from your dealer or an
authorized parts distributor. The chimney extension replaces the
chimney shipped with the range hood.
Venting Requirements
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
For the Most Efficient and Quiet Operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If the roof or wall cap
has a damper, do not use the damper supplied with the range
hood.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Venting Methods
Typical Internal Blower Motor System Venting Installations
A 10" (25.4 cm) round vent system is needed for installation (not
included). The range hood exhaust opening is 10" (25.4 cm)
round.
NOTE:
Flexible vent is not recommended. Flexible vent creates
back pressure and air turbulence that greatly reduce
performance.
Vent system can terminate either through the roof or wall. To vent
through the wall, a 90º elbow is needed.
Vented Installations
Min. ceiling height
Max. ceiling height
Electric cooking
surface
7'
9
" (2.36 m)
10'
2
" (3.1 m)
Gas cooking surface
8'
3
" (2.51 m)
10'
2
" (3.1 m)
18" (45.7 cm) min.
clearance upper
cabinet to countertop
X*
36" (91.4 cm)
countertop height
See Note*
36" (91.4 cm) or 48" (121.9 cm)
or cabinet opening width
(if installed between cabinets)
Roof Venting
Wall Venting
A. Roof cap
B. 10" (25.4 cm)
round vent
A. Wall cap
B. 10" (25.4 cm)
round vent
A
A
B
B