Konica Minolta AccurioPress C3080 AccurioPress C2070/C3080 Series Daily Mainte - Page 98
When a bleep sounds, slide FD-5BT while holding down
View all Konica Minolta AccurioPress C3080 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 98 highlights
3.6 Details of quality adjustment items 3 16 Stack 10 sheets of blank paper whose type is the same as that of the paper where chart has been print- ed, and place the printed chart on top of it. % Make sure that the arrow of the chart points up when you place the charts. 17 Measure charts from the left row (the row which has smaller numbers). % Hold down the side button of FD-5BT. When a "bleep" sounds, slide FD-5BT while holding down the side button. Slide FD-5BT to the bottom side, then release the side button. % For details about how to use FD-5BT, refer to the manual supplied with the spectrophotometer. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-27
AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L
3-27
3.6
Details of quality adjustment items
3
16
Stack 10 sheets of blank paper whose type is the same as that of the paper where chart has been print-
ed, and place the printed chart on top of it.
%
Make sure that the arrow of the chart points up when you place the charts.
17
Measure charts from the left row (the row which has smaller numbers).
%
Hold down the side button of
FD-5BT
. When a "bleep" sounds, slide FD-5BT while holding down
the side button. Slide FD-5BT to the bottom side, then release the side button.
%
For details about how to use
FD-5BT
, refer to the manual supplied with the spectrophotometer.