Kyocera FS C5020N FS-C5020/C5030 Operation Guide (Basic Edition) - Page 64
Printed Results, Corrective Action, Black or white vertical streaks, MENU], ENTER]
View all Kyocera FS C5020N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
Troubleshooting Printed Results Corrective Action Black or white vertical streaks Check the operator panel for toner. If the Toner low (C/M/Y/K) message is displayed with color description, install a new toner kit for the color. To replace the toner container, see Toner Container Replacement on page 4-3. Direction of Paper Feed Clean the main charger units. Open the left cover. Slowly pull the green wire cleaner knob to each of the main charger units in and out a few times. For full details, see Cleaning the Main Charger Unit on page 4-8. Clean the advanced beam array lenses. Open the left cover. Slowly pull the green lens cleaner knob in and out 2 times. For full details, see Cleaning the Advanced Beam Array Lenses on page 4-11. Refresh drum. Perform the following procedures on the operator panel and try cleaning the drum surface using the printer's built-in cleaning system. Faint or blurred printing 1 Press [MENU]. 2 Press U or V repeatedly until >Others appears. 3 Press Z. Press U or V repeatedly until >Service appears. 4 Press Z. Press U or V repeatedly until >>Drum appears. 5 Press [ENTER] twice. 6 The message display shows Please wait. After approx. 3 minutes, the display returns to Ready. Clean the main charger units. Open the left cover. Slowly pull the green wire cleaner knob to each of the main charger units in and out a few times. For full details, see Cleaning the Main Charger Unit on page 4-8. Clean the advanced beam array lenses. Open the left cover. Slowly pull the green lens cleaner knob in and out 2 times. For full details, see Cleaning the Advanced Beam Array Lenses on page 4-11. Make sure the paper type setting is correct the paper being used. See the Using the Operator Panel section in the Advanced Operation Guide. Conduct color calibration either by switching the printer off then on or using the printer operator panel. For full details, see the Using the Operator Panel section in the Advanced Operation Guide. Try adjusting the color control settings using the printer driver. Check the operator panel. If the Toner low (C/M/Y/K) message is displayed with color description, install a new toner kit for the color. To replace toner, see Toner Container Replacement on page 4-3. 5-4 BASIC OPERATION GUIDE