LG 50PC1DR Owners Manual - Page 11

Y SUSTAIN BOARD Troubleshooting - plasma

Page 11 highlights

Troubleshooting Y SUSTAIN BOARD Troubleshooting This Section of the Presentation will cover troubleshooting the Y SUS Board for the Single Scan Plasma. Upon completion of the Section the technician will have a better understanding of the operation of the circuit and will be able to locate voltage and resistance test points needed for troubleshooting and alignments. • Adjustments • DC Voltage and Waveform Checks • Resistance Measurements Operating Voltages SMPS Supplied VA 60v. VS 196v. 5v. Y SUS Developed VSC 115v. -VY -196v. IPM 18v. ER IPM SUS IPM Ramp UP V SET DN V SET UP Plasma Display Panel Troubleshooting - 2007 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

11
Plasma Display Panel Troubleshooting - 2007
Adjustments
DC Voltage and Waveform Checks
Resistance Measurements
Operating
Voltages
SMPS
Supplied
VA
60v.
VS
196v.
5v.
Y
SUS
Developed
VSC
115v.
-VY
-196v.
IPM
18v.
ER IPM
SUS IPM
Ramp UP
V SET DN
V SET UP
Troubleshooting
Y SUSTAIN BOARD Troubleshooting
This Section of the Presentation will cover troubleshooting the Y SUS Board for the Single
Scan Plasma. Upon completion of the Section the technician will have a better
understanding of the operation of the
circuit and will be able to locate voltage and
resistance test points needed for troubleshooting and alignments.