LG ARUN096BT2 Installation Manual - Page 8
Installation Process
View all LG ARUN096BT2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Installation Process Installation Process Determination of division work Indicate clearly who is to be responsible for switch settings Preparation of contract drawings Make relationship between outdoor, indoor, remote controller, and option connections clear. (Prepare control circuit diagram) Sleeve and insert work Installation of indoor unit Refrigerant piping work Drain pipe work Take account of gradient of drain piping Check model name to make sure the fitting is made correctly Special attention to dryness, cleanness and tightness Adjust to downward gradient Outdoor unit foundation work The foundation must be level even Installation of outdoor unit Avoid short circuits and ensure sufficient space is allowed for service Duct work Make sure airflow is sufficient Heat insulation work Make sure no gaps are left where the insulating materials are joined Electrical work (connection circuits and drive circuits) Multiple core cable must not be used. (suitable cable should be selected) Airtight test In the final check for 24hours at 3.8 MPa(38.7 kgf/cm2) there must be no drop in pressure. Vacuum drying Additional charge of refrigerant The vacuum pump used must have a capacity of reaching at least 5 torr, more than 1 hour Recharge correctly as calculated in this manual. and record the amount of added refrigerant Fit facing panels Make sure there are no gaps left between the facing materials used on the ceiling Automatic addressing of indoor unit Refer to automatic addressing flowchart Preheat the crank case with the electrical heater for more than 6 hours. Test run adjustment Run each indoor unit in turn to make sure the pipe work has been fitted correctly Transfer to customer with explanation Explain the use of the system as clearly as possible to your customer and make sure all relevant documentation is in order • The above list indicates the order in which the individual work operations are normally carried out but this order may be varied where local conditions warrants such change. • The wall thickness of the piping should comply with the relevant local and national regulations for the designed pressure 3.8MPa. • Since R410A is a mixed refrigerant, the required additional refrigerant must be charged in its liquid state.(If the refrigerant is charged in its gaseous state, its composition changes and the system will not work properly.) 8 Outdoor Unit