LG ARUN096BT2 Installation Manual - Page 9

Outdoor units Information - arun096dt2

Page 9 highlights

ENGLISH Outdoor units Information Installation Process CAUTION: Ratio of the connectable Indoor Units to the Outdoor: Within 50 ~ 130% Ratio of the running Indoor Units to the Outdoor: Within 10 ~ 100% A combination operation over 100% cause to reduce the total capacity. Power Supply: Outdoor Unit (3Ø, 460V, 60Hz) s Heat pump Unit System Model HP Ton Combination unit 8 6.5 ARUN076DT2 1 Outdoor Unit 10 12 14 8.0 9.5 11.0 ARUN096DT2 ARUN115DT2 ARUN134DT2 16 12.5 ARUN154DT2 Independent unit Product Charge kg(lbs) 8(17.6) 8(17.6) 8(17.6) 8(17.6) 8(17.6) CF(Correction Factor) kg(lbs) -1(-2.2) 0(0) 1(2.2) 2(4.4) 3(6.6) Max. Connectable No. of Indoor Units 13 16 19 23 26 Net Weight kg 240 285 285 285 285 lbs 529 628 628 628 628 Dimensions mm 1,280x1,607x730 1,280x1,607x730 1,280x1,607x730 1,280x1,607x730 1,280x1,607x730 (WxHxD) inch (50-3/8 x 63-5/16 x 28-11/16) (50-3/8 x 63-5/16 x 28-11/16) (50-3/8 x 63-5/16 x 28-11/16) (50-3/8 x 63-5/16 x 28-11/16) (50-3/8 x 63-5/16 x 28-11/16) Connecting Pipes Liquid Pipes[mm(inch)] 9.52(3/8) 9.52(3/8) 12.7(1/2) 12.7(1/2) 12.7(1/2) Gas Pipes[mm(inch)] 19.05(3/4) 22.2(7/8) 28.58(1 1/8) 28.58(1 1/8) 28.58(1 1/8) Unit 2 Outdoor Units System HP 18 20 22 24 Ton 14.5 16.0 17.5 19.0 Model Combination unit ARUN173DT2 ARUN192DT2 ARUN211DT2 ARUN230DT2 Independent unit ARUN096DT2 ARUN076DT2 ARUN115DT2 ARUN076DT2 ARUN134DT2 ARUN076DT2 ARUN154DT2 ARUN076DT2 Product Charge kg(lbs) 8+8(17.6+17.6) 8+8(17.6+17.6) 8+8(17.6+17.6) 8+8(17.6+17.6) CF(Correction Factor) kg(lbs) -1(-2.2) 0(0) 1(2.2) 2(4.4) Max. Connectable No. of Indoor Units 29 32 35 39 Net Weight kg 285+240 285+240 285+240 285+240 lbs 628+529 628+529 628+529 628+529 Dimensions mm (1,280x1,607x730)x2 (1,280x1,607x730)x2 (1,280x1,607x730)x2 (1,280x1,607x730)x2 (WxHxD) inch ((50-3/8 x 63-5/16 x 28-11/16) x 2) ((50-3/8 x 63-5/16 x 28-11/16) x 2) ((50-3/8 x 63-5/16 x 28-11/16) x 2) ((50-3/8 x 63-5/16 x 28-11/16) x 2) Connecting Pipes Liquid Pipes[mm(inch)] 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8) Gas Pipes[mm(inch)] 28.58(1 1/8) 28.58(1 1/8) 28.58(1 1/8) 34.9(1 3/8) Unit 2 Outdoor Units System HP 26 28 30 32 Ton 20.5 22.5 24.0 25.5 Model Combination unit ARUN250DT2 ARUN270DT2 ARUN290DT2 ARUN310DT2 Independent unit ARUN134DT2 ARUN115DT2 ARUN134DT2 ARUN134DT2 ARUN154DT2 ARUN134DT2 ARUN154DT2 ARUN154DT2 Product Charge kg(lbs) 8+8(17.6+17.6) 8+8(17.6+17.6) 8+8(17.6+17.6) 8+8(17.6+17.6) CF(Correction Factor) kg(lbs) 3(6.6) 4(8.8) 5(11.0) 6(13.2) Max. Connectable No. of Indoor Units 42 45 49 52 Net Weight kg 285x2 285x2 285x2 285x2 lbs 628x2 628x2 628x2 628x2 Dimensions mm (1,280x1,607x730)x2 (1,280x1,607x730)x2 (1,280x1,607x730)x2 (1,280x1,607x730)x2 (WxHxD) inch ((50-3/8 x 63-5/16 x 28-11/16) x 2) ((50-3/8 x 63-5/16 x 28-11/16) x 2) ((50-3/8 x 63-5/16 x 28-11/16) x 2) ((50-3/8 x 63-5/16 x 28-11/16) x 2) Connecting Pipes Liquid Pipes[mm(inch)] 19.05(3/4) 19.05(3/4) 19.05(3/4) 19.05(3/4) Gas Pipes[mm(inch)] 34.9(1 3/8) 34.9(1 3/8) 34.9(1 3/8) 34.9(1 3/8) Installation Manual 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91

ENGLISH
Installation Manual
9
Installation Process
Outdoor units Information
CAUTION:
Ratio of the connectable Indoor Units to the Outdoor: Within 50 ~ 130%
Ratio of the running Indoor Units to the Outdoor: Within 10 ~ 100%
A combination operation over 100% cause to reduce the total capacity.
Power Supply: Outdoor Unit (3Ø, 460V, 60Hz)
Heat pump
Unit
System
HP
Ton
Model
Combination unit
Independent unit
Product Charge
kg(lbs)
CF(Correction Factor)
kg(lbs)
Max. Connectable No. of Indoor Units
Net Weight
kg
lbs
Dimensions
mm
(WxHxD)
inch
Connecting Pipes
Liquid Pipes[mm(inch)]
Gas Pipes[mm(inch)]
1 Outdoor Unit
8
10
12
14
16
6.5
8.0
9.5
11.0
12.5
ARUN076DT2
ARUN096DT2
ARUN115DT2
ARUN134DT2
ARUN154DT2
8(17.6)
8(17.6)
8(17.6)
8(17.6)
8(17.6)
-1(-2.2)
0(0)
1(2.2)
2(4.4)
3(6.6)
13
16
19
23
26
240
285
285
285
285
529
628
628
628
628
1,280x1,607x730
1,280x1,607x730
1,280x1,607x730
1,280x1,607x730
1,280x1,607x730
(50-3/8 x 63-5/16 x 28-11/16)
(50-3/8 x 63-5/16 x 28-11/16) (50-3/8 x 63-5/16 x 28-11/16)
(50-3/8 x 63-5/16 x 28-11/16)
(50-3/8 x 63-5/16 x 28-11/16)
9.52(3/8)
9.52(3/8)
12.7(1/2)
12.7(1/2)
12.7(1/2)
19.05(3/4)
22.2(7/8)
28.58(1 1/8)
28.58(1 1/8)
28.58(1 1/8)
Unit
System
HP
Ton
Model
Combination unit
Independent unit
Product Charge
kg(lbs)
CF(Correction Factor)
kg(lbs)
Max. Connectable No. of Indoor Units
Net Weight
kg
lbs
Dimensions
mm
(WxHxD)
inch
Connecting Pipes
Liquid Pipes[mm(inch)]
Gas Pipes[mm(inch)]
2 Outdoor Units
18
20
22
24
14.5
16.0
17.5
19.0
ARUN173DT2
ARUN192DT2
ARUN211DT2
ARUN230DT2
ARUN096DT2
ARUN115DT2
ARUN134DT2
ARUN154DT2
ARUN076DT2
ARUN076DT2
ARUN076DT2
ARUN076DT2
8+8(17.6+17.6)
8+8(17.6+17.6)
8+8(17.6+17.6)
8+8(17.6+17.6)
-1(-2.2)
0(0)
1(2.2)
2(4.4)
29
32
35
39
285+240
285+240
285+240
285+240
628+529
628+529
628+529
628+529
(1,280x1,607x730)x2
(1,280x1,607x730)x2
(1,280x1,607x730)x2
(1,280x1,607x730)x2
((50-3/8 x 63-5/16 x 28-11/16) x 2)
((50-3/8 x 63-5/16 x 28-11/16) x 2)
((50-3/8 x 63-5/16 x 28-11/16) x 2)
((50-3/8 x 63-5/16 x 28-11/16) x 2)
15.88(5/8)
15.88(5/8)
15.88(5/8)
15.88(5/8)
28.58(1 1/8)
28.58(1 1/8)
28.58(1 1/8)
34.9(1 3/8)
Unit
System
HP
Ton
Model
Combination unit
Independent unit
Product Charge
kg(lbs)
CF(Correction Factor)
kg(lbs)
Max. Connectable No. of Indoor Units
Net Weight
kg
lbs
Dimensions
mm
(WxHxD)
inch
Connecting Pipes
Liquid Pipes[mm(inch)]
Gas Pipes[mm(inch)]
2 Outdoor Units
26
28
30
32
20.5
22.5
24.0
25.5
ARUN250DT2
ARUN270DT2
ARUN290DT2
ARUN310DT2
ARUN134DT2
ARUN134DT2
ARUN154DT2
ARUN154DT2
ARUN115DT2
ARUN134DT2
ARUN134DT2
ARUN154DT2
8+8(17.6+17.6)
8+8(17.6+17.6)
8+8(17.6+17.6)
8+8(17.6+17.6)
3(6.6)
4(8.8)
5(11.0)
6(13.2)
42
45
49
52
285x2
285x2
285x2
285x2
628x2
628x2
628x2
628x2
(1,280x1,607x730)x2
(1,280x1,607x730)x2
(1,280x1,607x730)x2
(1,280x1,607x730)x2
((50-3/8 x 63-5/16 x 28-11/16) x 2)
((50-3/8 x 63-5/16 x 28-11/16) x 2)
((50-3/8 x 63-5/16 x 28-11/16) x 2)
((50-3/8 x 63-5/16 x 28-11/16) x 2)
19.05(3/4)
19.05(3/4)
19.05(3/4)
19.05(3/4)
34.9(1 3/8)
34.9(1 3/8)
34.9(1 3/8)
34.9(1 3/8)