Troubleshooting CH04 Display code 04 Title Drain pump / Float switch Cause of error • Float switch Open. (Normal : short) CN Float Troubleshooting Guide Check point & Normal condition • The connection of wire(Drain pump/ Float switch) • Drain pump power input. (220V) • Drain tube installation. • Indoor unit installation. (Inclination) 0Ω Ω Check the resistance Check Point 1. Check the wire connection. (Open, Soldered poorly) ¡ Repair the connection or change the PCB. 2. Check the resistance of float switch (Abnormal : Open, Normal : short) ¡ Check the float switch. 3. Check the level of water 4. Check the volt. Of Drain pump power supply. (AC 230V) ¡ Repair or Change the main PCB. Service Manual 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61

Service Manual
41
Troubleshooting Guide
Troubleshooting CH04
Check the resistance
0
CN Float
04
Drain pump
/ Float switch
Float switch Open.
(Normal : short)
The connection of wire(Drain pump/ Float switch)
Drain pump power input. (220V)
Drain tube installation.
Indoor unit installation. (Inclination)
Display
code
Title
Cause of error
Check point & Normal condition
Check Point
1. Check the wire connection.
(Open, Soldered poorly)
Repair the connection or change the PCB.
2. Check the resistance of float switch (Abnormal : Open, Normal : short)
Check the float switch.
3. Check the level of water
4. Check the volt. Of
Drain pump power supply. (AC 230V)
Repair or Change the main PCB.