LG LWHD1800HR Service Manual - Page 19
Refrigeration cycle
View all LG LWHD1800HR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Disassembly Refrigeration cycle CAUTION: Discharge the refrigerant system using FreonTM Recovery System.If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. Leave the valve in place after servicing the system. 16. CONDENSER 1. Remove the cabinet. (Refer to section 2) 2. Remove the brace and the shroud cover. (Refer to section 4) 3. Remove 2 screws which fasten the side cover.(See Fig. 31) 4. Remove the 5 or 6 screws which fasten the condenser. 5. After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections. 6. Remove the condenser. 7. Re-install the components by referring to notes. (See Fig. 31) 17. EVAPORATOR 1. Remove the cabinet. (Refer to section 2) 2. Remove the top cover and the brace. (Refer to section 4) 3. Discharge the refrigerant completely. 4. Remove the 3 screws which fasten the evaporator at the left side and the top side. 5. Move the evaporator sideward carefully and then unbraze the interconnecting tube at the evaporator connectors. 6. Remove the evaporator. 7. Re-install the components by referring to notes. (See Fig. 32) Figure 31 18. CAPILLARY TUBE 1. Remove the cabinet. (Refer to section 2) 2. Remove the brace. (Refer to section 4) 3. After discharging the refrigerant completely, unbraze the interconnecting tube at the capillary tube. 4. Remove the capillary tube. 5. Re-install the components by referring to notes. Figure 32 19 Room Air Conditioner