LG MAB745W 01 Service Manual - Page 15

D. Door Gross Assembly Removal, E. High Voltage Transformer, Removal, F. Fan Motor Assembly Removal

Page 15 highlights

D. DOOR GROSS ASSEMBLY REMOVAL 1) Open the door. 2) Remove the choke cover very carefully with a flat-blade screwdriver. CAUTION : Be careful not to damage door seal plate by screwdriver. 3) Lift up and push the door. NOTE: 1. After replacing the door, be sure to check that the primary switch, monitor switch, and secondary switch operate normally. 2. After replacing the door, check for microwave energy leakage with a survey meter. Microwave energy must be below the limit of 5 mW/cm. (with a 275 ml water load) 3. When mounting the door assembly to the oven assembly, be sure to adjust the door assembly parallel to the chassis. Also adjust so the door has no play between the inner door surface and oven frame assembly. If the door assembly is not mounted properly, microwaves may leak from the clearance between the door and the oven. Remove choke cover E. HIGH VOLTAGE TRANSFORMER REMOVAL 1) Discharge the high voltage capacitor. 2) Disconnect the leadwire from magnetron, high voltage transformer, and capacitor. 3) Remove the screw holding the high voltage transformer to the baseplate. F. FAN MOTOR ASSEMBLY REMOVAL 1) Discharge the high voltage capacitor. 2) Disconnect the leadwire from fan motor, and high voltage capacitor. 3) Remove the two screws holding the the suction guide ASS'Y to the oven cavity and remove the high voltage diode earth screw. 4) Remove the two screws holding the fan motor ASS'Y to the suction guide ASS'Y. G. HIGH VOLTAGE CAPACITOR AND DIODE REMOVAL 1) Discharge the high voltage capacitor. 2) Disconnect the leadwire from fan motor, and high voltage capacitor. 3) Remove the screw holding the suction guide ASS'Y to the oven cavity and remove the high voltage diode earth screw. 4) Remove the screw holding the high voltage capacitor bracket. Remove door 5-4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35

D. DOOR GROSS ASSEMBLY REMOVAL
1) Open the door.
2) Remove the choke cover very carefully with a
flat-blade screwdriver.
CAUTION : Be careful not to damage door seal plate
by screwdriver.
3) Lift up and push the door.
NOTE:
1. After replacing the door, be sure to check that the
primary switch, monitor switch, and secondary switch
operate normally.
2. After replacing the door, check for microwave energy
leakage with a survey meter. Microwave energy must
be below the limit of 5 mW/cm. (with a 275 ml water
load)
3. When mounting the door assembly to the oven
assembly, be sure to adjust the door assembly parallel
to the chassis. Also adjust so the door has no play
between the inner door surface and oven frame
assembly. If the door assembly is not mounted
properly, microwaves may leak from the clearance
between the door and the oven.
E. HIGH VOLTAGE TRANSFORMER
REMOVAL
1) Discharge the high voltage capacitor.
2) Disconnect the leadwire from magnetron, high voltage
transformer, and capacitor.
3) Remove the screw holding the high voltage
transformer to the baseplate.
F. FAN MOTOR ASSEMBLY REMOVAL
1) Discharge the high voltage capacitor.
2) Disconnect the leadwire from fan motor, and high
voltage capacitor.
3) Remove the two screws holding the the suction guide
ASS
Y to the oven cavity and remove the high voltage
diode earth screw.
4) Remove the two screws holding the fan motor ASS
Y
to the suction guide ASS
Y.
G. HIGH VOLTAGE CAPACITOR AND
DIODE REMOVAL
1) Discharge the high voltage capacitor.
2) Disconnect the leadwire from fan motor, and high
voltage capacitor.
3) Remove the screw holding the suction guide ASS
Y to
the oven cavity and remove the high voltage diode
earth screw.
4) Remove the screw holding the high voltage capacitor
bracket.
5-4
Remove choke cover
Remove door