LG MAB745W 01 Service Manual - Page 24

CONDITION, CHECK, RESULT, CAUSE, REMEDY, TROUBLE 2 Oven does not operate at all, Display window does

Page 24 highlights

(TROUBLE 2) Oven does not operate at all, Display window does not display any figures, and no input is accepted. CONDITION 1. Fuse blows. CHECK Check continuity of monitor switch (with door closed). Replace fuse RESULT Continuity. No continuity. CAUSE Malfunction of the monitor switch. REMEDY Replace fuse, primary, monitor, secondary switches, and RELAY(RY2) of P.C.B Assembly. Check continuity of primary switch (with door opened) Disconnect one side of the wire lead connected from transformer to the high voltage capacitor and operate the unit. Continuity. No continuity. Normal. Fuse blows again Shorted contact at the primary switch. Defective high voltage capacitor. Defective high voltage transformer. Replace fuse, primary, monitor, secondary switches, and RELAY(RY2) of P.C.B Assembly. Replace high voltage capacitor. Replace high voltage transformer. NOTE : All these switches must be replaced at the same time. Refer to page 5-7, 5-8 2. Fuse does not blow. Check continuity of thermostat. No continuity. Continuity. Defective thermostat. Replace thermostat. Check continuity of power supply cord. No continuity. Defective power supply cord. Replace power supply cord. 5-13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35

5-13
2. Fuse does not
blow.
No continuity.
Continuity.
No continuity.
Defective power
supply cord.
Replace power
supply cord.
Defective
thermostat.
Replace
thermostat.
Check continuity
of thermostat.
Check continuity
of power supply
cord.
NOTE : All these switches must be replaced at the same time. Refer to page 5-7, 5-8
CONDITION
CHECK
RESULT
CAUSE
REMEDY
(TROUBLE 2) Oven does not operate at all, Display window does not display any figures,
and no input is accepted.
1. Fuse blows.
Continuity.
No continuity.
Malfunction of the
monitor switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
Check continuity
of monitor
switch (with
door closed).
Continuity.
No continuity.
Shorted contact at
the primary switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
Check continuity
of primary
switch (with
door opened)
Normal.
Replace fuse
Fuse blows again
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Defective high volt-
age transformer.
Replace high volt-
age transformer.