LG MAB745W 01 Service Manual - Page 21

When Removing The Wire Leads From The Parts, Be Sure To Grasp

Page 21 highlights

COMPONENTS RELAY 2 TEST PROCEDURE Check for continuity of relay 2 with an ohm-meter. (Remove wire leads from relay 2 and operate the unit.) RESULTS POWER LEVEL 1 4 sec 2 6 sec 3 8 sec 4 10 sec 5 12 sec 6 14 sec 7 16 sec 8 18 sec 9 20 sec 10 22 sec 18 sec 16 sec 14 sec 12 sec 10 sec 8 sec 6 sec 4 sec 2 sec 0 sec FAN MOTOR (Wire leads removed) Measure the resistance. (Ohm-meter scale: R x 100) Normal: A~B : Approx. 65 ~ 80 ohm B~C : Approx. 10 ~ 30 ohm A~C : Approx. 85 ~ 105 ohm Abnormal: Infinite or several ohm. TURNTABLE MOTOR (Wire leads removed) Measure the resistance. (Ohm-meter scale: R x 1000) Normal: Approx. 100 ~ 150 ohm Abnormal: Infinite or several ohm. NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS SERVICED FOR ANY REASON. • MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION. • WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE CONNECTOR, NOT THE WIRES. 5-10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35

5-10
COMPONENTS
TEST PROCEDURE
RESULTS
RELAY 2
FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Check for continuity of relay 2 with an
ohm-meter.
(Remove wire leads from relay 2 and
operate the unit.)
NOTE :
A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
Relay 1
Relay 2
A(RD)
B(BK)
C(WH)
Measure the resistance.
(Ohm-meter scale: R x 1000)
Normal:
A~B : Approx. 65 ~ 80 ohm
B~C : Approx. 10 ~ 30 ohm
A~C : Approx. 85 ~ 105 ohm
Abnormal: Infinite or several
ohm.
Normal: Approx. 100 ~ 150 ohm
Abnormal: Infinite or several
ohm.
POWER
LEVEL
1
2
3
4
5
6
7
8
9
10
4 sec
6 sec
8 sec
10 sec
12 sec
14 sec
16 sec
18 sec
20 sec
22 sec
18 sec
16 sec
14 sec
12 sec
10 sec
8 sec
6 sec
4 sec
2 sec
0 sec
Measure the resistance.