Lantronix SISTP1040-551-LRT SISTP1040-551-LRT Install Guide Rev B - Page 15
Alarm Relay Connection
View all Lantronix SISTP1040-551-LRT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Lantronix SISTP1040-551-LRT Install Guide Alarm Relay Connection The alarm relay output contacts (ALM) are located in the middle of the DC terminal block connector as shown right and below. By inserting the wires and setting the DIP switch of the respective Port Alarm to "ON", the relay output alarm will detect any port failures and form a short circuit. The alarm relay is "Normal Open" and it will be "Closed" when any power failure is detected. The alarm relay output contacts have a current carrying capacity of 24VDC, 1Amp, via the 2-pin ALM terminal block. 33841 Rev. B https://www.lantronix.com/ Page 15 of 26
Lantronix
SISTP1040-551-LRT Install Guide
33841 Rev. B
/
Page
15
of
26
Alarm Relay Connection