Lenovo NetVista Hardware Maintenance Manual (HMM) for NetVista 2271, 6840, and - Page 66

Run Setup and verify Configuration, POST Error Code

Page 66 highlights

POST Error Code 08X Check SCSI terminator installation. 101 System board interrupt failure 102 System board timer error 106 110 System board memory parity error 111 I/O channel parity error 114 Adapter ROM error 129 Internal cache test error 151 Real-time clock failure 161 Bad CMOS battery 162 Configuration mismatch 162 And unable to run diagnostics FRU/Action 1. SCSI Cable 2. SCSI Terminator 3. SCSI Device 4. SCSI Adapter 1. System Board 1. System Board 1. System Board 1. Memory Module 2. System Board 1. Reseat adapters 2. Any adapter 3. Riser card 4. System Board 1. Adapter Memory 2. System Board 3. Riser card 1. Processor 2. L2 Cache Memory 3. System Board 1. System Board 1. Run Setup 2. CMOS Backup Battery (see "Safety Information" on page 125) 3. System Board 1. Run Setup and verify Configuration 2. Had a device been added, removed, changed location? If not, suspect that device. 3. Power-on external devices first, then power-on computer 4. CMOS Backup Battery (see "Safety Information" on page 125) System Board 5. System Board 6. Riser card 1. Diskette Drive 2. System Board 3. Diskette Drive Cable 4. Riser card 60 Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271: IBM NetVista Computer

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

POST Error Code
FRU/Action
08X
Check SCSI terminator installation.
1.
SCSI Cable
2.
SCSI Terminator
3.
SCSI Device
4.
SCSI Adapter
101
System board interrupt failure
1.
System Board
102
System board timer error
1.
System Board
106
1.
System Board
110
System board memory parity error
1.
Memory Module
2.
System Board
111
I/O channel parity error
1.
Reseat adapters
2.
Any adapter
3.
Riser card
4.
System Board
114
Adapter ROM error
1.
Adapter Memory
2.
System Board
3.
Riser card
129
Internal cache test error
1.
Processor
2.
L2 Cache Memory
3.
System Board
151
Real-time clock failure
1.
System Board
161
Bad CMOS battery
1.
Run Setup
2.
CMOS Backup Battery (see “Safety
Information” on page 125)
3.
System Board
162
Configuration mismatch
1.
Run Setup and verify Configuration
2.
Had a device been added, removed,
changed location? If not, suspect that
device.
3.
Power-on external devices first, then
power-on computer
4.
CMOS Backup Battery (see “Safety
Information” on page 125)
System Board
5.
System Board
6.
Riser card
162
And unable to run diagnostics
1.
Diskette Drive
2.
System Board
3.
Diskette Drive Cable
4.
Riser card
60