Diagnostic Error Code 018-197-XXX PCI Card test warning 018-198-XXX PCI Card test aborted 018-199-XXX PCI Card test failed, cause unknown 018-250-XXX PCI Card Services error 020-000-XXX PCI Interface Test Passed 020-0XX-XXX PCI Interface error 020-195-XXX PCI Test aborted by user 020-196-XXX PCI test halt, error threshold exceeded 020-197-XXX PCI test warning FRU/Action 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, "Using the Setup Utility," on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, "Using the Setup Utility," on page 51 2. Flash the system and re-test. See "Flash update procedures" on page 243 3. Go to "Undetermined problems" on page 81 1. Go to "Undetermined problems" on page 81 2. Flash the system and re-test. See "Flash update procedures" on page 243 3. Replace component under function test 1. PCI card 2. Riser card, if installed 3. System board No action 1. PCI card 2. Riser card, if installed 3. System board Information only Re-start the test, if necessary 1. Press F3 to review the log file 2. Re-start the test to reset the log file 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, "Using the Setup Utility," on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 66 Hardware Maintenance Manual