POST error codes, Power-On Self-Test
View all Lenovo ThinkStation E31 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 70 highlights
The following tables describes beep symptoms. Beep Symptom 2 short beeps CMOS setting error 3 short beeps and then 1 long beep DRAM memory error FRU/Action Perform the following actions in order. 1. Start the Setup Utility program and press F10 to Save and exit. See Chapter 6 "Using the Setup Utility program" on page 53. 2. Start the Setup Utility program and press F9 to load defaults and then press F10 to Save and exit. 3. Perform a Boot-block recovery. See "Recovering from a POST/BIOS update failure" on page 168. Perform the following actions in order. 1. Make sure the memory module(s) are properly seated in the connector(s). 2. Replace the memory module(s). 3. Replace the system board. POST error codes Each time you power-on the system, it performs a series of tests that check the operation of the system and some options. This series of tests is called the Power-On Self-Test, or POST. POST does the following operations. • Checks some basic system-board operations • Checks the memory operation • Starts the video operation • Verifies that the boot drive is working If the POST detects a problem, an error message appears on the screen. A single problem can cause several error messages to appear. When you correct the cause of the first error message, the other error messages probably will not appear on the screen the next time you turn on the system. POST Error code 00CE 0211 0135 POST Error message Description/Action Machine Type or Serial Number is INVALID This error message is displayed when the machine type or the serial number is invalid. Keyboard not found This error message is displayed when there is no keyboard detected. Fan failure The system might be overheating. Press F1 to enter the Setup Utility program. Then press F10 to save and exit the Setup Utility program. 0164 Memory size decreased Note: If the problem is caused by the microprocessor fan, pressing F10 will not solve the problem. This error message is displayed when the memory size has decreased. Press F1 to enter the Setup Utility program. Then press F10 to save and exit the Setup Utility program. 64 ThinkStation Hardware Maintenance Manual