LiftMaster 8010 8010 Owner s Manual - Page 20
Wire the Safety Reversing Sensors, AINSTALLATION WITHOUT PRE-WIRING
View all LiftMaster 8010 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Installation 14 Wire the Safety Reversing Sensors If your garage already has wires installed for the safety reversing sensors, see page 21. HARDWARE 1 2 Staple Insulated Staple (Not Shown) OPTION A INSTALLATION WITHOUT PRE-WIRING 1. Run the wire from both sensors to the garage door opener. Attach the wire to the wall and ceiling with the staples. 2. Strip 7/16 inch (11 mm) of insulation from each set of wires. Separate the wires. Twist the white wires together. Twist the white/black wires together. 3. Insert the white wires into the white terminal on the garage door opener. Insert the white/black 3 wires into the grey terminal on the garage door opener. To insert or remove the wires from the terminal, push in the tab with a screwdriver tip. 7/16" (11 mm) RED WHITE WHITE GREY 20