Install the Safety Reversing Sensors

Page 18 highlights

Install the Protector System® 1 Install the Safety Reversing Sensors The safety reversing sensors can be attached to the door track, the wall, or the floor. If the door track will not support the sensor bracket a wall installation is recommended. Choose one of the following installations. HARDWARE H12 (2) Carriage Bolt 1/4"-20x1/2" OPTION A DOOR TRACK INSTALLATION 1.1A Slide the curved arms of the sensor bracket around the edge of the door track. Snap into place so that the sensor bracket is flush against the track. 1.2A Slide the carriage bolt (H12) into the slot on each sensor. 1.3A Insert the bolt through the hole in the sensor bracket and attach with the wing nut (H13). The lenses on both sensors should point toward each other. Make sure the lens is not obstructed by the sensor bracket. H13 (2) Wing Nut 1/4"-20 H13 H12 OPTION B WALL INSTALLATION If additional clearance is needed an extension bracket (not provided) or wood blocks can be used. Make sure each bracket has the same amount of clearance so they will align correctly. 1.1B Position the sensor bracket against the wall with the curved arms facing the door. Make sure there is enough clearance for the beam to be unobstructed. Mark holes. 1.2B Drill 3/16 inch pilot holes for each sensor bracket and attach the sensor brackets to the wall using lag screws (not provided). 1.3B Slide the carriage bolt (H12) into the slot on each sensor. 1.4B Insert the bolt through the hole in the sensor bracket and attach with the wing nut (H13). The lenses on both sensors should point toward each other. Make sure the lens is not obstructed by the sensor bracket. (not provided) IGWnasairldal ege (not provided) H13 H12 Lens 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Install the Protector System
®
1
Install the Safety Reversing Sensors
The safety reversing sensors can be attached to the door track, the wall, or the floor. If the door track will not support the sensor bracket a wall installation is recommended. Choose one of the following installations.
HARDWARE
H12 (2)
Carriage Bolt
1/4"-20x1/2"
H13 (2)
Wing Nut
1/4"-20
OPTION
A
DOOR TRACK INSTALLATION
1.1A
Slide the curved arms of the sensor
bracket around the edge of the door
track. Snap into place so that the
sensor bracket is flush against the
track.
1.2A
Slide the carriage bolt (H12) into the
slot on each sensor.
H12
1.3A
Insert the bolt through the hole in the sensor
bracket and attach with the wing nut (H13). The
lenses on both sensors should point toward
each other. Make sure the lens is not obstructed
by the sensor bracket.
H13
OPTION
B
WALL INSTALLATION
If additional clearance is needed an extension bracket (not provided) or wood blocks can be used. Make sure each bracket has the same amount of clearance so they will align correctly.
1.1B
Position the sensor bracket against the
wall with the curved arms facing the
door. Make sure there is enough
clearance for the beam to be
unobstructed.Markholes.
(not provided)
1.2B
Drill 3/16 inch pilot holes for each
sensor bracket and attach the sensor
brackets to the wall using lag screws
(not provided).
Inside
Garage
Wall
(not provided)
1.3B
Slide the carriage bolt (H12) into the
slot on each sensor.
H12
Lens
1.4B
Insert the bolt through the hole in the sensor
bracket and attach with the wing nut (H13). The
lenses on both sensors should point toward
each other. Make sure the lens is not
obstructed by the sensor bracket.
H13