OPTIONAL PROGRAMMING FEATURES CONT'D Timer To Close ON Feature: Installer can set a timer to automatically close after a preset amount ON of time once all safety devices are unobstructed. SET TIMER TO CLOSE Benefits: Door will automatically close after being used. Extremely conven- 1 2 3 4 ient where users may not be concerned with closing the door. For example Apartment Buildings and Fire Stations. OFF Requirements: Must have at least one of the following safety devices attached: CPS-L, CPS-LN4, CPSII, CPSII-N4. When running, the dip switches must be set for TS, T, or FSTS Press This To Get This To Program: 1. Close the door. 2. Set dip switches to "Set Timer To Close" 3. Press "close" to zero out the timer. 4. Press "open" for every 5 seconds seconds the operator should wait before attempting to close the door. Example: The door is supposed to close 30 seconds after the user drives through. To set the TTC for 30 seconds press close, then open 6 times. 5. Return the dip switches to the desired wiring type. TS, T, or FSTS Notes: For longer delay time settings, use the Single Button Control (terminal 1) to add 1 minute at a time. To deactivate the timer press stop. The timer will be reactivated on the next operation command. Open Close Stop Single Button Control Adds 5 seconds to countdown timer. Resets the timer to close to 0 seconds. Turns off electronic search for photo eyes after photo eyes have been intentionally removed. Adds 5 seconds to "Red warning light before closing" time. Adds 60 seconds to countdown timer. Reminders: FSTS wiring mode allows the Timer To Close to be activated by the Single Button Control (terminal 1) only. T wiring mode allows the door to attempt to close only one time for safety purposes. Adjusting your red/green warning lights Feature: The logic board can adjust the amount of time that a warning light will flash before the Timer To Close will activate the door to close. Benefit: Advanced warning of door closure helps prevent traffic collisions with the door. To Program: 1. Set the dip switches to "Set Timer To Close" 2. Press stop for every additional 5 seconds of pre-movement warning. 3. Return the dip switches to the desired wiring type. Requirements: Must have the Logic 2 red green warning light kit #001A4730 and must have at least one of the following safety devices attached: CPS-L, CPS-LN4, CPSII, CPSII-N4. When running, the dip switches must be set for TS, T, or FSTS. See red/green warning light instructions for further details. 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

18
OPTIONAL PROGRAMMING FEATURES CONT’D
Adjusting your red/green warning lights
Feature:
The logic board can adjust the amount of time that a warning light
will flash before the Timer To Close will activate the door to close.
Benefit:
Advanced warning of door closure helps prevent traffic collisions
with the door.
To Program:
1.
Set the dip switches to "Set Timer To Close"
2.
Press stop for every additional 5 seconds of pre-movement warning.
3.
Return the dip switches to the desired wiring type.
Requirements:
Must have the Logic 2 red green warning light kit
#001A4730 and must have at least one of the following safety devices
attached: CPS-L, CPS-LN4, CPSII, CPSII-N4.
When running, the dip switch-
es must be set for TS, T, or FSTS.
See red/green warning light instructions
for further details.
T
imer T
o Close
Feature:
Installer can set a timer to automatically close after a preset amount
of time once all safety devices
are unobstructed.
Benefits:
Door will automatically close after being used.
Extremely conven-
ient where users may not be concerned with closing the door. For example
Apartment Buildings and Fire Stations.
Requirements:
Must have at least one of the following safety devices
attached: CPS-L, CPS-LN4, CPSII, CPSII-N4.
When running, the dip switches
must be set for TS, T, or FSTS
To Program:
1.
Close the door.
2.
Set dip switches to "Set Timer To Close"
3.
Press "close" to zero out the timer.
4.
Press "open" for every 5 seconds seconds the operator should wait before
attempting to close the door.
Example:
The door is supposed to close 30 seconds after the user drives
through.
To set the TTC for 30 seconds press close, then open 6
times.
5.
Return the dip switches to the desired wiring type. TS, T, or FSTS
Notes:
For longer delay time settings, use the Single Button Control (terminal
1) to add 1 minute at a time.
To deactivate the timer press stop.
The timer will
be reactivated on the next operation command.
Reminders:
FSTS wiring mode allows the Timer To Close to be activated by
the Single Button Control (terminal 1) only.
T wiring mode allows the door to
attempt to close only one time for safety purposes.
SET
TIMER
TO CLOSE
1
2
3
4
ON
ON
OFF
Open
Close
Stop
Single Button
Control
Adds 5 seconds to
countdown timer.
Resets the timer to
close to 0 seconds.
Turns off electronic
search for photo eyes
after photo eyes have
been intentionally
removed.
Adds 5 seconds to
“Red warning light
before closing” time.
Adds 60 seconds to
countdown timer.