LiftMaster GH GH LOGIC VERSION 2 Manual - Page 18
Optional Programming Features Cont'd
View all LiftMaster GH manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
OPTIONAL PROGRAMMING FEATURES CONT'D Timer To Close ON Feature: Installer can set a timer to automatically close after a preset amount ON of time once all safety devices are unobstructed. SET TIMER TO CLOSE Benefits: Door will automatically close after being used. Extremely conven- 1 2 3 4 ient where users may not be concerned with closing the door. For example Apartment Buildings and Fire Stations. OFF Requirements: Must have at least one of the following safety devices attached: CPS-L, CPS-LN4, CPSII, CPSII-N4. When running, the dip switches must be set for TS, T, or FSTS Press This To Get This To Program: 1. Close the door. 2. Set dip switches to "Set Timer To Close" 3. Press "close" to zero out the timer. 4. Press "open" for every 5 seconds seconds the operator should wait before attempting to close the door. Example: The door is supposed to close 30 seconds after the user drives through. To set the TTC for 30 seconds press close, then open 6 times. 5. Return the dip switches to the desired wiring type. TS, T, or FSTS Notes: For longer delay time settings, use the Single Button Control (terminal 1) to add 1 minute at a time. To deactivate the timer press stop. The timer will be reactivated on the next operation command. Open Close Stop Single Button Control Adds 5 seconds to countdown timer. Resets the timer to close to 0 seconds. Turns off electronic search for photo eyes after photo eyes have been intentionally removed. Adds 5 seconds to "Red warning light before closing" time. Adds 60 seconds to countdown timer. Reminders: FSTS wiring mode allows the Timer To Close to be activated by the Single Button Control (terminal 1) only. T wiring mode allows the door to attempt to close only one time for safety purposes. Adjusting your red/green warning lights Feature: The logic board can adjust the amount of time that a warning light will flash before the Timer To Close will activate the door to close. Benefit: Advanced warning of door closure helps prevent traffic collisions with the door. To Program: 1. Set the dip switches to "Set Timer To Close" 2. Press stop for every additional 5 seconds of pre-movement warning. 3. Return the dip switches to the desired wiring type. Requirements: Must have the Logic 2 red green warning light kit #001A4730 and must have at least one of the following safety devices attached: CPS-L, CPS-LN4, CPSII, CPSII-N4. When running, the dip switches must be set for TS, T, or FSTS. See red/green warning light instructions for further details. 18