LiftMaster GH GH LOGIC VERSION 2 Manual - Page 7

Notice - door opener

Page 7 highlights

ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL) CONT'D PHOTO EYES & SENSING EDGES Sensing devices supplied for door industry type operators NOTICE with an isolated normally open (N.O.) dry contact output are compatible with your operator. This includes through beam and retro reflective photo eyes, and pneumatic and electric edges. If your door does not have bottom safety IT IS STRONGLY RECOMMENDED THAT A SAFETY PHOTO EYE OR SENSING EDGE BE USED IN CONJUNCTION WITH THE OPERATOR. photo eyes or a sensing edge and you wish to add a safe- ty device to your application, please contact your local WIRING: For wiring of your sensing device to the LiftMaster Authorized Dealer. operator, refer to the wiring diagram on pages 11-13. See field connection terminals identified as Reversing Device. If not pre-installed by the door manufacturer, mount the sensing edge on the door according to the instructions pro- vided with the edge. The sensing edge may be electrical- TAKE-UP REEL: Take-up reel should be installed 12" ly connected by either coiled cord or take-up reel. above the top of the door. Important Notes: COIL CORD: Connect operator end of coil cord to a) Proceed with Limit Switch Adjustments before making junction box (not supplied) fastened to the wall any sensing edge wiring connections to operator as approximately halfway up the door opening. described below. b) Electrician must hardwire the junction box to the operator electrical box in accordance with local codes. LIMIT SWITCH ADJUSTMENT MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE PROCEEDING WITH ADJUSTMENTS. 1. To adjust limit nuts depress retaining plate to allow nut to spin freely. After adjustment, release plate and ensure it seats fully in slots of both nuts. 2. To increase door travel, spin nut away from actuator. To decrease door travel, spin limit nut toward actuator. 3. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening. 4. Repeat Steps 1 and 2 for close cycle. Adjust close limit nut so that actuator is engaged as door fully seats at the floor. WARNING TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS. If other problems persist, call our toll-free number for CAUTION assistance - 1-800-528-2806. CLOSE Limit Switch OPEN Limit Switch Actuator WA SAFETY (Aux. Close) Limit Switch 7 Retaining Plate

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

7
TO AVOID SERIOUS PERSONAL INJURY OR DEATH
FROM ELECTROCUTION, DISCONNECT ELECTRIC
POWER BEFORE MANUALLY MOVING LIMIT NUTS.
WARNING
LIMIT SWITCH ADJUSTMENT
MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE
PROCEEDING WITH ADJUSTMENTS.
If other problems persist, call our toll-free number for
assistance - 1-800-528-2806.
1.
To adjust limit nuts depress retaining plate to allow
nut to spin freely.
After adjustment, release plate
and ensure it seats fully in slots of both nuts.
2.
To
increase
door travel, spin nut
away
from actu-
ator. To
decrease
door travel, spin limit nut
toward
actuator.
3.
Adjust open limit nut so that door will stop in open
position with the bottom of the door even with top
of door opening.
4.
Repeat Steps 1 and 2 for close cycle. Adjust close
limit nut so that actuator is engaged as door fully
seats at the floor.
PHOTO EYES & SENSING EDGES
Sensing devices supplied for door industry type operators
with an isolated normally open (N.O.) dry contact output
are compatible with your operator. This includes through
beam and retro reflective photo eyes, and pneumatic and
electric edges.
If your door does not have bottom safety
photo eyes or a sensing edge and you wish to add a safe-
ty device to your application, please contact your local
LiftMaster Authorized Dealer.
If not pre-installed by the door manufacturer, mount the
sensing edge on the door according to the instructions pro-
vided with the edge.
The sensing edge may be electrical-
ly connected by either coiled cord or take-up reel.
Important Notes:
a)
Proceed with Limit Switch Adjustments before making
any sensing edge wiring connections to operator as
described below.
b)
Electrician must hardwire the junction box to the oper-
ator electrical box in accordance with local codes.
ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL) CONT’D
WIRING: For wiring of your sensing device to the
operator, refer to the wiring diagram on pages 11-13.
See field connection terminals identified as
Reversing Device.
TAKE-UP REEL: Take-up reel should be installed 12"
above the top of the door.
COIL CORD:
Connect operator end of coil cord to
junction box (not supplied) fastened to the wall
approximately halfway up the door opening.
IT IS STRONGLY
RECOMMENDED THAT A
SAFETY PHOTO EYE OR SENSING EDGE BE
USED IN CONJUNCTION WITH THE OPERATOR.
NOTICE
Retaining Plate
CLOSE
Limit S
w
itch
SAFETY
(A
u
x. Close) Limit S
w
itch
OPEN
Limit S
w
itch
Act
u
ator