LiftMaster LMSC1000 Installation Manual - English French Spanish - Page 5
Wiegand Interface Module Programming, Beeper Enable/Disable, Antenna Range Adjustment
View all LiftMaster LMSC1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Wiegand Interface Module Programming Power Serial Wiegand RESET Loop PWR RF PWR SET LP SET/ERR SER I SER 0 WO SETUP 6 DC LOOP 5 8SEC 4 4SEC 3 2SEC 2 1SEC 1 ON - OFF Dry Cont SETUP 6 LOOP 5 8SEC 4 4SEC 3 2SEC 2 1SEC 1 ON - OFF Wiegand Retransmission Delay The S2W Wiegand Interface Module has an adjustable Wiegand output retransmission delay from 0-15 seconds. When enabled, the S2W Wiegand Interface will transmit 1 Wiegand pulse and start the timer. If a tag remains in the active reading zone, the S2W Wiegand Interface will not transmit another pulse until the timer expires. The delay is set using the bottom 4 dip-switches shown above. When the switch is set to the left it is in the "On" position. Use the chart to the right to select the desired amount of retransmission delay (in seconds). The default setting is 3 seconds delay. NOTE: The power to the S2W Wiegand Interface must be cycled for any switch changes to take effect. Antenna Range Adjustment The S2W Wiegand Interface Module has an antenna range adjustment located on the circuit board just left of the LED Display. To adjust the range perform the following steps: 1. Place the module in programming mode by setting switch 6 to "On"(left). 2. Locate the adjustment pot and turn clockwise to increase range or counter-clockwise to decrease range. The LED display will show the relative power setting (Max is all LEDs on). 3. To send the new range setting to the reader press the Reset button just above the range adjustment. 4. Once the desired range is set, place the module into operating mode by setting switch 6 (Setup) to "Off" (right). 1 2 3 4 Delay (Seconds) Off Off Off Off 0 On Off Off Off 1 Off On Off Off 2 On On Off Off 3 Off Off On Off 4 On Off On Off 5 Off On On Off 6 On On On Off 7 Off Off Off On 8 On Off Off On 9 Off On Off On 10 On On Off On 11 Off Off On On 12 On Off On On 13 Off On On On 14 On On On On 15 Power RESET Loop Serial Wiegand PWR RF PWR SET LP SET/ERR SER I SER 0 WO DC SETUP 6 LOOP 5 8SEC 4 4SEC 3 2SEC 2 1SEC 1 ON - OFF Dry Cont Beeper Enable/Disable By default, the LMSC1000 will beep when it reads an RFID tag. To toggle this feature (turn on or off) perform the following steps: 1. Place the module in programming mode by setting switch 6 (Setup) to "On" (left). 2. Turn the adjustment pot counter-clockwise to the minimum setting. 3. Press the Reset button just above the range adjustment to toggle the setting. 4. Return the antenna range setting to its original position. 5. Press the Reset button just above the range adjustment to set range. 6. Place the module into operating mode by setting switch 6 to "Off" (right). 5