MSI 790GX User Guide - Page 96

Sata Raid

Page 96 highlights

Appendix C SATA RAID SATA RAID The 710 / 750 integrate one SATA host controller separately, and support RAID function for performance and reliability. SATA RAID provides support for RAID 0 (Striping), RAID 1 (Mirroring), RAID 0+1 (Striping & Mirroring) & RAID 5 (striping with parity). RAID 0 greatly improves hard disk I/O performance by concurrently striping data across multiple drives. RAID 1 makes sure data is not lost if a drive f ails as data is simultaneously written to two drives. Drives configured for RAID Striping are said to form a RAID 0 set, while drives configured for RAID Mirroring are said to form a RAID 1 set. RAID 0+1 is implemented as a mirrored array whose segments are RAID 0 arrays. RAID 0+1 has same fault tolerance as mirroring and reduces overhead by striping. It needs at least four drives to form a RAID 0+1. RAID 5 defines techniques for parity data. *Only 750 supports RAID 5. C-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

C-1
SATA RAID
Appendix C
The 710 / 750 integrate one SATA host controller
separately, and support RAID function for performance
and reliability.
SATA RAID provides support for RAID 0 (Striping), RAID
1 (Mirroring), RAID 0+1 (Striping & Mirroring) & RAID 5
(striping with parity). RAID 0 greatly improves hard disk
I/O performance by concurrently striping data across
multiple drives. RAID 1 makes sure data is not lost if a
drive fails as data is simultaneously written to two
drives. Drives configured for RAID Striping are said to
form a RAID 0 set, while drives configured for RAID
Mirroring are said to form a RAID 1 set. RAID 0+1 is
implemented as a mirrored array whose segments are
RAID 0 arrays. RAID 0+1 has same fault tolerance as
mirroring and reduces overhead by striping. It needs at
least four drives to form a RAID 0+1. RAID 5 defines
techniques for parity data.
*Only 750 supports RAID 5.