SEC Error Codes 0C - 0D Reserved for future AMI SEC error codes 0E Microcode not found 0F Microcode not loaded PEI Progress Codes 10 11 12 - 14 15 16 - 18 PEI Core is started Pre-memory CPU initialization is started Pre-memory CPU initialization (CPU module specific) Pre-memory System Agent initialization is started Pre-Memory System Agent initialization (System Agent module specific) 19 Pre-memory PCH initialization is started 1A - 1C Pre-memory PCH initialization (PCH module specific) 2B 2C 2D 2E 2F 31 32 33 34 35 36 37 38 - 3A 3B Memory initialization. Serial Presence Detect (SPD) data reading Memory initialization. Memory presence detection Memory initialization. Programming memory timing information Memory initialization. Configuring memory Memory initialization (other) Memory Installed CPU post-memory initialization is started CPU post-memory initialization. Cache initialization CPU post-memory initialization. Application Processor(s) (AP) initialization CPU post-memory initialization. Boot Strap Processor (BSP) selection CPU post-memory initialization. System Management Mode (SMM) initialization Post-Memory System Agent initialization is started Post-Memory System Agent initialization (System Agent module specific) Post-Memory PCH initialization is started 62