Magic Chef MCSRG24S User Manual 1 - Page 18

Series Of Products

Page 18 highlights

note: The triple burner has only two injectors, one injector mounted in the center and another mounted below the cover plate. To access the second injector, remove the two screws and the cover plate. 24" Burner and Orifice Characteristic Table Refer to the following chart for correct gas orifice spud placement. important: Save the orifices removed from the appliance for future use. Burner Auxiliary Semi-Rapid Triple Rapid Position Front R Rear L Front L Raer R Orifice Diam. (mm) 0.9 0.58 1.17 0.75 0.93 + 1.82 1.14 + 0.56 1.6 1.03 Gas Type NG LP (Propane) NG LP (Propane) NG LP (Propane) NG LP (Propane) Pressure [i.w.c] 4" 10" 4" 10" 4" 10" 4" 10" Rate [BTU/h] 5000 5000 6859 6859 17357 15000 6859 6859 24" SERIES OF PRODUCTS Gas Type: Natural Gas 4" Test Point Pressure Burner Large Small Tiny Top Burner Bottom Burner Gas Type: LPG 10" Test Point Pressure Burner Large Small Tiny Top Burner Bottom Burner Injector Size (mm) 0.99 mm x 5 1.29 mm 1.10 mm 1.40 mm 1.70 mm Injector Size (mm) 0.56 mm x 5 0.80 mm 0.70 mm 0.85 mm 1.10 mm Burner Rating (BTU) 17400 6900 5000 7900 10700 Burner Rating (BTU) 15000 6500 5000 7900 10800 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

18
NOTE
: The triple burner has only two injectors, one injector mounted in the center and another mounted below
the cover plate� To access the second injector, remove the two screws and the cover plate�
24” Burner and Orifice Characteristic Table
Refer to the following chart for correct gas orifice spud placement�
IMPORTANT
: Save the orifices removed from the appliance for future use�
Burner
Position
Orifice
Gas
Pressure
Rate
Diam� (mm)
Type
[i�w�c]
[BTU/h]
Auxiliary
Front R
0�9
NG
4”
5000
0�58
LP (Propane)
10”
5000
Semi-Rapid
Rear L
1�17
NG
4”
6859
0�75
LP (Propane)
10”
6859
Triple
Front L
0�93 + 1�82
NG
4”
17357
1�14 + 0�56
LP (Propane)
10”
15000
Rapid
Raer R
1�6
NG
4”
6859
1�03
LP (Propane)
10”
6859
24” SERIES OF PRODUCTS
Gas Type: Natural Gas 4” Test Point Pressure
Burner
Injector Size (mm)
Burner Rating (BTU)
Large
0�99 mm x 5
17400
Small
1�29 mm
6900
Tiny
1�10 mm
5000
Top Burner
1�40 mm
7900
Bottom Burner
1�70 mm
10700
Gas Type: LPG 10” Test Point Pressure
Burner
Injector Size (mm)
Burner Rating (BTU)
Large
0�56 mm x 5
15000
Small
0�80 mm
6500
Tiny
0�70 mm
5000
Top Burner
0�85 mm
7900
Bottom Burner
1�10 mm
10800