Product Dimensions - Double Oven A B E Cabinet Side View - Double or Single Oven A B E C D D C A. 22¹⁄₄" (56.8 cm) max. recessed width B. 46 117.6 cm) max. overall height C. 23⁷⁄₈" (60.6 cm) overall width D. 22⁵⁄₈" (57.5 cm) max. recessed depth E. 44³⁄₄" (113.4 cm) recessed height A. 24" (61 cm) min. cutout depth B. 22⁵⁄₈" (57.5 cm) recessed oven depth C. Oven front D. Recessed oven E. Cabinet Electrical Requirements WARNING Cabinet Dimensions - Double Oven Double Oven Installed in Cabinet A B F D E C A. 24" (61 cm) min. cabinet width B. 1¹⁄₂" (3.8 cm) top of cutout to bottom of upper cabinet door C. 14" (35.6 cm) min. bottom of cutout to floor D. 22³⁄₈" (56.8 cm) cutout width E. 1¹⁄₂" (3.8 cm) min. bottom of cutout to top of cabinet door F. 45³⁄₈" (115.3 cm) cutout height NOTE: For gas supply pipe, provide a 3" x 3" opening in the back wall of the cabinet centered 7" from the left rear corner and 3" above the bottom of the cabinet cutout. Install a 120 volt electrical outlet in the back wall of the cabinet centered 6" from the right rear corner and 4" below the top of the cabinet cutout. Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. IMPORTANT: The oven must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1. If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate. A copy of the above code standards can be obtained from: National Fire Protection Association One Batterymarch Park Quincy, MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland, OH 44131-5575 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

4
Product Dimensions - Double Oven
Cabinet Dimensions - Double Oven
Double Oven Installed in Cabinet
NOTE:
For gas supply pipe, provide a 3" x 3" opening in the back
wall of the cabinet centered 7" from the left rear corner and 3"
above the bottom of the cabinet cutout. Install a 120 volt electrical
outlet in the back wall of the cabinet centered 6" from the right
rear corner and 4" below the top of the cabinet cutout.
Cabinet Side View - Double or Single Oven
Electrical Requirements
IMPORTANT:
The oven must be electrically grounded in
accordance with local codes and ordinances, or in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70 or
Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A. 22
¹⁄₄
" (56.8 cm) max. recessed width
B. 46
⁵⁄₁₆
" (117.6 cm) max. overall height
C. 23
⁷⁄₈
" (60.6 cm) overall width
D. 22
⁵⁄₈
" (57.5 cm) max. recessed depth
E. 44
³⁄₄
" (113.4 cm) recessed height
A.
24
" (61 cm) min. cabinet width
B. 1
¹⁄₂
" (3.8 cm) top of cutout to bottom of upper
cabinet door
C. 14" (35.6 cm) min. bottom of cutout to floor
D. 22
³⁄₈
" (56.8 cm) cutout width
E. 1
¹⁄₂
" (3.8 cm) min. bottom of cutout to top of
cabinet door
F. 45
³⁄₈
" (115.3 cm) cutout height
A
B
D
E
C
A
B
C
D
E
F
A. 24" (61 cm) min. cutout depth
B. 22
⁵⁄₈
" (57.5 cm) recessed oven depth
C. Oven front
D. Recessed oven
E. Cabinet
A
B
C
D
E
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING