Motorola 68230 Operation Guide - Page 71

DSU Troubleshooting

Page 71 highlights

DSU Troubleshooting Introduction Use the following information to help troubleshoot potential installation problems. Potential Installation Problems Installation problems may include the following: • Improper telephone company interface connection • Incorrect DSU port Clock Source option • No signal from telephone company interface CTP-Derived Information The following information may be derived from the CTP. Function Node Statistics Port Statistics Monitor DSU Internal Loopback used to... • verify that the software is a version that contains the DSU option modifications. • show if the software recognizes the DSU. • verify that data is sent without error; error counts may denote an error in clocking mode configuration. • show if the software recognizes the DSU. • determine, via input/output signals, if the DSU option is in a loopback mode requested by the remote end (which would result in an inability to send data); continuous bipolar violations indicate the remote system is out of service. • indicate a failure of this loopback mode, meaning a connection has not been made.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79

DSU Troubleshooting
Introduction
Use the following information to help troubleshoot potential installation
problems.
Potential Installation Problems
Installation problems may include the following:
Improper telephone company interface connection
Incorrect DSU port Clock Source option
No signal from telephone company interface
CTP-Derived Information
The following information may be derived from the CTP.
Function
used to...
verify that the software is a version that contains
the DSU option modifications.
Node Statistics
show if the software recognizes the DSU.
verify that data is sent without error; error counts
may denote an error in clocking mode
configuration.
Port Statistics
show if the software recognizes the DSU.
Monitor
determine, via input/output signals, if the DSU
option is in a loopback mode requested by the
remote end (which would result in an inability to
send data); continuous bipolar violations indicate
the remote system is out of service.
DSU Internal Loopback
indicate a failure of this loopback mode, meaning
a connection has not been made.