Netgear FSM7226RS FSM7226RS / FSM7250RS Hardware Installation Guide
Netgear FSM7226RS - ProSafe Switch - Stackable Manual
UPC - 606449059915
View all Netgear FSM7226RS manuals
Add to My Manuals
Save this manual to your list of manuals |
Netgear FSM7226RS manual content summary:
- Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 1
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide NETGEAR, Inc. 350 E. Plumeria Drive San Jose, CA 95134 USA 202-10454-01 October 2008 - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 2
is hereby certified that the NETGEAR ProSafe™ 24-Port L2+ Managed Stackable Switch with 2 Gigabit ports FSM7226RS has been suppressed in accordance the notes in the operating instructions. It is hereby certified that the NETGEAR ProSafe™ 48-Port L2+ Managed Stackable Switch with 2 Gigabit ports - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 3
and used in accordance with the instructions, cause harmful interference to radio by turning the equipment off and on, the user is encouraged to try to correct the interference certify that the NETGEAR ProSafe™ 24-Port L2+ Managed Stackable Switch with 2 Gigabit ports FSM7226RS is shielded against - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 4
appropriate measures. Customer Support Refer to the Support Information Card that shipped with your ProSafe™ 24-Port L2+ Managed Stackable Switch with 2 Gigabit ports FSM7226RS or ProSafe™ 48-Port L2+ Managed Stackable Switch with 2 Gigabit ports FSM7250RS. World Wide Web NETGEAR maintains a World - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 5
How to Print This Manual viii Revision History ...ix Chapter 1 Introduction FSM7226RS Front Panel and LEDs 1-1 FSM7226RS Rear Panel 1-2 FSM7250RS Front Panel and LEDs 1-2 FSM7250RS Rear Panel 1-3 Interpreting the LEDs ...1-3 Safety Instructions ...1-4 Chapter 2 Hardware Installation Package - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 6
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide Chapter 3 Troubleshooting Troubleshooting Chart 3-1 Additional Troubleshooting Suggestions 3-2 Appendix A Default Factory Settings and Technical Specifications Default Configuration Settings A-1 Technical - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 7
About This Manual The NETGEAR® Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide describes how to install, configure and troubleshoot the managed switches. The information in this manual is intended for readers with intermediate computer and Internet skills. - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 8
2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide • Scope. This manual is written for the Managed Layer 2+ Stackable Fast Ethernet Switch according to these specifications: Product Version Manual Publication Date ProSafe FSM7200RS October 2008 How to Use This Manual The - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 9
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide - Printing a PDF version of the complete manual. Use the Complete PDF Manual link at the top left corner of any page. • Click the Complete PDF Manual link at the top left corner of any page in the manual. The PDF - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 10
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide x v1.0, October 2008 - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 11
, and increase productivity. This guide describes hardware installation and basic troubleshooting for the following NETGEAR switches: • ProSafe™ 24-Port L2+ Managed Stackable Switch with 2 Gigabit ports FSM7226RS • ProSafe™ 48-Port L2+ Managed Stackable Switch with 2 Gigabit ports FSM7250RS - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 12
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide FSM7226RS Rear Panel The rear panel has two FSM7250RS Front Panel and LEDs The following figure shows the front panel of the managed switch. The front panel contains LEDs, a RST (reset) button, RJ-45 jacks, - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 13
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide FSM7250RS Rear Panel The rear RPS (redundant power supply) Stack Master Description • Solid green: Power is supplied and the switch is working. • Blinking green. Power-on self-test (POST) in progress. • Solid - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 14
Switches FSM7226RS and FSM7250RS Hardware Installation Guide Table 1-1. LED Descriptions (continued) LED Stack ID • RJ45 Port 1-24 for FSM7226RS • RJ45 Port 1-48 for FSM7250RS (One LED per port) Stack ports (IN and OUT) • Copper port 25-26 for FSM7226RS port. Safety Instructions Use the following - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 15
Switches FSM7226RS and FSM7250RS Hardware Installation Guide - The product has been exposed to water. - The product has been dropped or damaged. - The product does not operate correctly when you follow the operating instructions proper grounding. Do not use adapter plugs or remove the grounding prong - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 16
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide • Observe extension cable and power strip ratings. Make sure that the total ampere rating of all products plugged into the extension cable or power strip - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 17
7200RS Series Layer-2 Stackable Switches, the NETGEAR 7000 Series Managed Switch Administration Guide, the NETGEAR Installation Guide for the 7000 Series Stackable Managed Switch, and this Hardware Installation Guide • Warranty and Support Card • ProSafe NMS100 Network Management System 30-day - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 18
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide Protecting Against Electrostatic Discharge Note: If any item is found missing or damaged, contact your local NETGEAR reseller for replacement. 5. Inspect the products and accessories for damage. Report any - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 19
Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide Installation Install the equipment in the following sequence, as presented in this chapter: 1. Select a location. See "Selecting a Location" on page 2-3. 2. Install the switch. See "Installing the Switch" on page - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 20
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide Table 2-1. Site Requirements for Switch Location (continued) Requirements Cabling Route the cable to avoid sources of electrical noise such as radio transmitters, broadcast amplifiers, power lines, and - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 21
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide 3. Tighten the screws with a No. 1 the AC power adapter cable to the rear of the switch, and the other end to a grounded three-pronged AC outlet. 2. Check the Power LED on the front panel of the switch. The LED - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 22
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide SFP Modules The module bay accommodates a standard SFP module with an LC connector that is compatible with the IEEE 802.3z 1000BASE-X standard. SFP modules - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 23
section of the screen. When the product support screen displays, look for the Certified RPS Power Supplier link. Stacking You can connect up to eight switches to form a stack with a single management IP address. The switches automatically select a master unit. Once the master is selected, you - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 24
Switches FSM7226RS and FSM7250RS Hardware Installation Guide 3. Connect each switch to the next in a cascade to build the backplane of the stack. Finally, connect the last switch in the stack to the first switch (CLI) to identify the IP address. If you are stacking switches, see "Stacking" on page - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 25
this purpose: • Command Line Interface Reference for the ProSafe 7200RS Series Layer-2 Stackable Switches: Gives detailed examples of how to use the CLI, and is located on the Resource CD. • NETGEAR 7000 Series Managed Switch Administration Guide: Describes configuration tasks, and is located on the - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 26
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide 2-10 v1.0, October 2008 Hardware Installation - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 27
of possible problems. Table 3-1. Troubleshooting Problem Cause Solution Power LED is off. No power is received • Check the power cord connections for the switch at the switch and the connected device. • Make sure that all cables used are correct and comply with Ethernet specifications. Link - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 28
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide Additional Troubleshooting Suggestions If the suggestions in Table 3-1 on page 3-1 do not resolve your problem, refer to the troubleshooting suggestions in this section. • Network Adapter Cards Make sure that the - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 29
Specifications Default Configuration Settings This section provides the default settings for the FSM7226RS and FSM7250RS switches. control Enabled Gigabit port type Auto detect Management IP configuration DHCP Password protection Disabled User name Admin Password (none) Web access - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 30
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide Table A-1. Default Configuration Settings (continued) Features ACL GVRP GMRP IP routing MAC address aging SNMP community DHCP Server VLAN Ingress filtering IP multicast filtering Default Setting Disabled - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 31
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide Table A-2. Technical Specifications (continued) Feature Switch management Layer 2 Services Layer 3 Services FSM7226RS FSM7250RS • Port mirroring support • SNMP v1, v2c, v3 • RFC1757 RMON 1 groups 1, 2, 3, - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 32
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide Table A-2. Technical Specifications (continued) Feature FSM7226RS FSM7250RS Interface (Auto Uplink on all RJ-45 ports) • 24 RJ-45 connectors for 10BASE-T, 100BASE-TX • 2 gigabit interface converter (SFP) - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 33
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide Table A-2. Technical Specifications (continued) Feature FSM7226RS FSM7250RS Electromagnetic emissions and immunity Safety • CE mark, commercial • FCC Part 15 Class A VCCI • Class A EN 55022 (CISPR 22) Class - Netgear FSM7226RS | FSM7226RS / FSM7250RS Hardware Installation Guide - Page 34
Managed Layer 2+ Stackable Switches FSM7226RS and FSM7250RS Hardware Installation Guide A-6 Default Factory Settings and Technical Specifications v1.0, October 2008
202-10454-01
October 2008
NETGEAR
, Inc.
350 E. Plumeria Drive
San Jose, CA 95134 USA
Managed Layer 2+
Stackable Switches
FSM7226RS and
FSM7250RS Hardware
Installation Guide