Onkyo CP-1050 User Manual English - Page 9
Stylus pressure, Anti-skating
View all Onkyo CP-1050 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
2. Stylus pressure First turn the scale of the stylus pressure temporarily to "0" in a horizontally balanced state, and then adjust the stylus pressure. If the stylus pressure is too high or too low, the record may not be played back correctly, or the stylus life may be shortened, or the record may be damaged. Be sure to adjust the stylus pressure to an appropriate value to match the cartridge. 1. Turn the stylus pressure adjustment ring so that the white center line on the shaft at the back of the tone arm is at "0". 0 Keep your fingers in contact with the stylus pressure adjustment ring only and turn it so that the counterweight does not turn at the same time. Counterweight Preparatory adjustments 2. Turn the counterweight in the direction of the arrow so that the white center line on the shaft at the back of the tone arm is at "3.5". 0 When the counterweight is turned, the stylus pressure adjustment ring also turns. 0 When using a cartridge and head shell other than those supplied, adjust the stylus pressure to an appropriate value to match the cartridge after readjusting the horizontal balance. Center line Stylus pressure adjustment ring 3. Anti-skating When playing a record, a force pulling the stylus tip towards the inner circumference is generated. This force can be canceled by setting the anti-skating value to the same stylus pressure. 1. Turn the anti-skating knob to adjust it to the same scale as the stylus pressure. If the stylus pressure is "3.0" or higher like the supplied cartridge, adjust it to "3". Anti-skating knob 9