Optoma EH615T EH615T User Manual - Page 15
the enclosure does not exceed operation temperature while the projector is running, and the air intake
View all Optoma EH615T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
SETUP AND INSTALLATION Allow at least 50 cm clearance around the exhaust vent. Minimum 500mm (19.69 inches) Minimum 500mm (19.69 inches) Minimum 500mm (19.69 inches) Minimum 100mm (3.94 inches) Minimum 500mm (19.69 inches) Minimum 300mm (11.81 inches) Ensure that the intake vents do not recycle hot air from the exhaust vent. When operating the projector in an enclosed space, ensure that the surrounding air temperature within the enclosure does not exceed operation temperature while the projector is running, and the air intake and exhaust vents are unobstructed. All enclosures should pass a certified thermal evaluation to ensure that the projector does not recycle exhaust air, as this may cause the device to shutdown even if the enclosure temperature is with the acceptable operation temperature range. English 15