Panasonic AG-HPX250PJ Operating Instructions - Page 60

Configuration of setup data files

Page 60 highlights

Using scene files (Scene File Data) (continued) Configuration of setup data files This camera makes it possible to save a scene file to each of the F1 to F6 positions on the SCENE FILE dial. Use of an SD memory card makes it possible to save up to four of the F1 to F6 files on an SD card for later retrieval. The setting menu values can be stored as a user file in the camera-recorder and up to four files can be stored on the SD memory card. The setting data files are configured as shown below. AG-HPX250P/AG-HPX250EN SD CARD SCENE FILE (Factory defaults) SCENE FILE (Current operating status values) SCENE FILE (Saved camera values) F1 Default value F2 Default value SCENE FILE screen INTIAL *1 F1 Current value F2 Current value SCENE FILE screen LOAD/SAVE *1 F1 Saved value F2 Saved value F3 Default value F3 Current value F3 Saved value F4 Default value F4 Current value F4 Saved value F5 Default value F5 Current value F5 Saved value F6 Default value F6 Current value F6 Saved value *1: SCENE FILE dial unit *2: All files F1 to F6 CARD FUNCTIONS screen SCENE FILE  LOAD/SAVE *2 SCENE FILE (SD CARD) F1 F2 SCENE F3 FILE 1 F4 F5 F6 F1 F2 SCENE F3 FILE 2 F4 F5 F6 F1 F2 SCENE F3 FILE 3 F4 F5 F6 F1 F2 SCENE F3 FILE 4 F4 F5 F6 USER FILE (Factory defaults) USER FILE (Current operating status values) USER FILE (Saved camera values) USER FILE initial value Current USER FILE values Saved USER FILE values OTHER FUNCTIONS screen OTHER FUNCTIONS screen USER FILE  INTIAL USER FILE  LOAD/SAVE CARD FUNCTIONS screen USER FILE  LOAD/SAVE USER FILE (SD CARD) USER FILE1 USER FILE2 USER FILE3 USER FILE4 • Running the menu option MENU INIT in the OTHER FUNCTIONS screen returns all current operating status values and saved camera-recorder values in the F1 to F6 scene files as well as in the user file to their factory defaults. This function does not return the TIMEZONE setting to its factory default. • SCENE FILE and USER FILE settings cannot be operated when recordings can be compiled to a previous clip in one-clip recording mode (i.e., when "1 CLIP" is displayed). After closing the menu, push the Operation lever in the ▼ direction (STOP) for approximately 2 seconds, and try once more after ending clip linking. 60

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170

60
Configuration of setup data files
This camera makes it possible to save a scene file to each of the F1 to F6 positions on the SCENE FILE
dial.
Use of an SD memory card makes it possible to save up to four of the F1 to F6 files on an SD card for later
retrieval.
The setting menu values can be stored as a user file in the camera-recorder and up to four files can be
stored on the SD memory card.
The setting data files are configured as shown below.
F1 Default value
SCENE FILE
(Factory defaults)
SCENE FILE
screen INTIAL
*1
SCENE FILE screen
LOAD/SAVE
*1
F2 Default value
F3 Default value
F4 Default value
F5 Default value
F6 Default value
F1 Current value
SCENE FILE
(Current operating status values)
F2 Current value
F3 Current value
F4 Current value
F5 Current value
F6 Current value
F1 Saved value
SCENE FILE
(Saved camera values)
F1
F2
F3
F4
F5
F6
SCENE
FILE 1
F1
F2
F3
F4
F5
F6
SCENE
FILE 2
F1
F2
F3
F4
F5
F6
SCENE
FILE 3
F1
F2
F3
F4
F5
F6
SCENE
FILE 4
USER FILE1
USER FILE2
USER FILE3
USER FILE4
USER FILE initial value
USER FILE
(Factory defaults)
OTHER FUNCTIONS screen
USER FILE
INTIAL
OTHER FUNCTIONS screen
USER FILE
LOAD/SAVE
CARD FUNCTIONS screen
SCENE FILE
LOAD/SAVE
*2
*1: SCENE FILE dial unit
*2: All files F1 to F6
Current USER FILE values
USER FILE
(Current operating status values)
Saved USER FILE values
USER FILE
(Saved camera values)
SCENE FILE
(SD CARD)
USER FILE
(SD CARD)
F2 Saved value
F3 Saved value
F4 Saved value
F5 Saved value
F6 Saved value
CARD FUNCTIONS screen
USER FILE
LOAD/SAVE
AG-HPX250P/AG-HPX250EN
SD CARD
Running the menu option MENU INIT in the OTHER FUNCTIONS screen returns all current
operating status values and saved camera-recorder values in the F1 to F6 scene files as well as
in the user file to their factory defaults. This function does not return the TIMEZONE setting to
its factory default.
SCENE FILE and USER FILE settings cannot be operated when recordings can be compiled to
a previous clip in one-clip recording mode (i.e., when “1
CLIP” is displayed). After closing the
menu, push the Operation lever in the ▼ direction (STOP) for approximately 2 seconds, and try
once more after ending clip linking.
Using scene files (Scene File Data) (continued)