Panasonic AWE655 AWE350 User Guide - Page 20

Connection Of A Remote Control Box Rcb, Aw-ca50b10 And Wv-ca10b02m

Page 20 highlights

s CONNECTION OF A REMOTE CONTROL BOX (RCB) The RCB (WV-CB700A) and the camera must be connected with the optional RCB cable AW-CA50T10. 1. Turn RCB power off before connecting cables. 2. Connect the 50-pin connector of the RCB cable to I/F REMOTE connector of the camera. The 10-pin connector must be connected to the RCB. 3. Turn RCB power on and the camera can be controlled remotely by the RCB. Notes: • The monitor output signals of the RCB attenuate and deteriorate with cable length. It is recommended that the signals from the monitor output be used for monitoring purposes only. • No gen-lock signal is available from the RCB. • If a longer distance (more than 3 m) is desired between the camera and the RCB, use the following optional cable. AW-CA50B10 and WV-CA10B02 (2 m) WV-CA10B25 (25 m) WV-CA10B50 (50 m) RCB Cable AW-CA50T10 (3 m) DC Power Cable AW-CA4T1 Video signal IN MONITOR OUT RCB FUSE O I FUSE AC Adaptor AW-PS505 RCB WV-CB700A -20-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

-20-
CONNECTION OF A REMOTE CONTROL BOX (RCB)
The RCB (WV-CB700A) and the camera must be con-
nected with the optional RCB cable AW-CA50T10.
1.
Turn RCB power off before connecting cables.
2. Connect the 50-pin connector of the RCB cable to
I/F REMOTE connector of the camera. The 10-pin
connector must be connected to the RCB.
3. Turn RCB power on and the camera can be con-
trolled remotely by the RCB.
Notes:
The monitor output signals of the RCB attenuate
and deteriorate with cable length. It is recommend-
ed that the signals from the monitor output be used
for monitoring purposes only.
No gen-lock signal is available from the RCB.
If a longer distance (more than 3 m) is desired
between the camera and the RCB, use the following
optional cable.
AW-CA50B10 and WV-CA10B02 (2 m)
WV-CA10B25 (25 m)
WV-CA10B50 (50 m)
O
I
FUSE
FUSE
AC Adaptor
AW-PS505
Video signal IN
RCB WV-CB700A
RCB Cable AW-CA50T10 (3 m)
MONITOR OUT
DC Power Cable
AW-CA4T1
RCB