Sub_rtx_intvl_[1-8], Reg_rtx_intvl_[1-8], Sip_p_preferred_id_[1-8]
View all Panasonic KXTGP550 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 193 highlights
4.7.2 SIP Settings Value Format Description Value Range Default Value Integer Specifies the length of time, in seconds, that the subscription remains valid. This value is set in the "Expires" header of the SUBSCRIBE request. 1-4294967295 3600 SUB_RTX_INTVL_[1-8] Parameter Name Example Value Format Description Value Range Default Value SUB_RTX_INTVL_1, SUB_RTX_INTVL_2, ..., SUB_RTX_INTVL_8 Integer Specifies the interval, in seconds, between transmissions of SUBSCRIBE requests when a subscription results in failure (server no reply or error reply). 10-86400 10 REG_RTX_INTVL_[1-8] Parameter Name Example Value Format Description Value Range Default Value REG_RTX_INTVL_1, REG_RTX_INTVL_2, ..., REG_RTX_INTVL_8 Integer Specifies the interval, in seconds, between transmissions of the REGISTER request when a registration results in failure (server no reply or error reply). 10-86400 10 SIP_P_PREFERRED_ID_[1-8] Parameter Name Example Value Format Description Value Range Default Value SIP_P_PREFERRED_ID_1, SIP_P_PREFERRED_ID_2, ..., SIP_P_PREFERRED_ID_8 Boolean Specifies whether to add the "P-Preferred-Identity" header to SIP messages. • Y (Add the "P-Preferred-Identity" header) • N (Do not add the "P-Preferred-Identity" header) N Document Version 2010-08 Administrator Guide 193