Panasonic WJ-HD616/1000 Installation Guide - Page 94
Con the settings relating to RS485 [RS485 setup]
View all Panasonic WJ-HD616/1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 94 highlights
Configure the settings relating to RS485 [RS485 setup] Select the [RS485 setup] tab on the "Communication" page. (☞ Page 60) The settings for RS485 can be configured on this tab. [Protocol] Select the protocol used for RS485 communication. Panasonic/Pelco-D Default: Panasonic [Baud rate] Select a communication speed for data transmission with a connected device from the following: 2 400/4 800/9 600/19 200/38 400 (bps) Default: 19 200 [Control camera ch] Allocate the RS485 port 1 and port 2 to camera channels. When the [Setup] button is selected, the following page will be displayed. [Data bit] The data length for communication will be displayed. 7/8 (bit) Default: 8 [Parity] Methods of error check for a transmission at communication will be displayed. NONE: No parity check EVEN: Even parity ODD: Odd parity Default: NONE [Stop bit] Stop bit types will be displayed. 1/2 (bit) Default: 1 • [TERM] Select a port to be controlled from the following for each camera channel. PORT1: Controls from the RS485 port 1. PORT2: Controls from the RS485 port 2. • [Back] button Closes the setup page and returns to the [RS485 setup] tab. 94