Panasonic WVCU650 Operating Instructions - Page 18
SETUP PROCEDURES (HARDWARE), Setup Procedures, MODE Switch Setting, CONTROLLER NO. Switch Setting
UPC - 791871504277
View all Panasonic WVCU650 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
SETUP PROCEDURES (HARDWARE) ■ Setup Procedures Perform the setup as follows. 1. Set the MODE switches. You will set up the communication mode and line termination ON/OFF of RS-485 communication. (Refer to MODE Switch Setting.) 2. Set CONTROLLER NO. switches. You will perform this setting when using two or more system controllers in daisy chain connections. (Refer to CONTROLLER NO. Setting.) 3. Perform WV-CU650 setups after entering the administrator password. You will perform the settings concerning password and communication between system controllers and other system units, etc. (Refer to p. 19.) Note: Before performing WV-CU650 setups, you need to log into the system by entering the administrator password. (Refer to p. 19.) ■ MODE Switch Setting You will perform the setting of the MODE switches at the rear panel. Notes: • Before the setting, turn off the system controller. (Refer to p. 27 Power-off.) • Do not move the MODE switches to positions other than described in these illustrations. That may cause malfunction. ● Setting for PS·Data Mode If using only one system controller Set the MODE Switch #5 to ON. 1 2 3 4 5 67 8 OFF ON MODE Switch #5 (Line termination switch) If using two or more system controllers in daisy chain connections 1. Set the MODE Switch #5 of the system controller at the chain end to ON. 18 2. Set the Line termination switch of other system controllers to OFF. 1 2 3 4 5 67 8 OFF ON System units Line termination ON Line termination OFF Line termination OFF Line termination OFF Line termination ON ● Setting for Terminal Mode Set the MODE Switch #1 and #5 to ON. 1 2 3 4 5 67 8 OFF ON Note: Refer to the following document for details on connections and operations. Addendum for WV-CU650 and WJ-SX150 Series ■ CONTROLLER NO. Switch Setting You will determine controller-number settings by moving the CONTROLLER NO. switch at the rear panel. If using only one system controller Maintain the switch setting as "1 (factory default position)". If using two or more system controllers in daisy chain connections Up to 4 system controllers are connectable in the system. To avoid conflict, set the unique number for each system controller. 901 CONTROLLER No. Notes: • "0" and "9" are reserved numbers. They cannot be set for controller numbers. • One of the system controllers must be set to "1". 78 23 456