Panasonic XE9WKUA Full Line Catalog - Page 28

Deluxe Series Wall-Mount Heat Pump

Page 28 highlights

Deluxe Series Wall-Mount Heat Pump E9RKUA / E12RKUA E18RKUA / E24RKUA INDOOR UNIT CS-E9RKUAW / CS-E12RKUAW INDOOR UNIT CS-E18RKUAW / CS-E24RKUAW (E18 only) Wireless Controller (Included) Wired Remote Controller (CZ-RD516C-1) (Optional) Wireless Controller (Included) OUTDOOR UNIT CU-E9RKUA / CU-E12RKUA OUTDOOR UNIT CU-E18RKUA / CU-E24RKUA Cooling only operation may be configured during installation. Pipe diameters listed below are for single zone only. Multi zone pipe diameters on page 58. Model No. Unit Model No. Performance & Electrical Ratings Capacity Cooling Btu/h Heating Btu/h Moisture Removal High Pints/H Dry Air Flow High CFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps Cooling Heating A A Power Input Cooling Heating W W Min. Circuit Ampacity A Max. Overcurrent Protection A Features Controls Low Ambient Control Wireless Controller Wired Remote Controller(optional) Fan Speeds Timer Air Deflection Horizontal Vertical Advanced Air Purification Features Evaporator Guard Filter PM2.5 (CZ-SA31P) Anti Microbial (CZ-SA20P) Refrigerant Refrigerant control Operation Sound In (Hi / Me / Lo) dB-A Outdoor (Hi) dB-A Refrigerant Piping (single zone) Type Discharge Suction inches inches Refrigerant Pipe Length Ft. Elevation Difference* Outdoor Above Ft. Outdoor Below Ft. Dimensions & Weight Height inches Width inches Depth inches Net Weight Lbs. WALL MOUNT HEAT PUMPS E9RKUA Indoor Unit Outdoor Unit CS-E9RKUAW CU-E9RKUA E12RKUA Indoor Unit Outdoor Unit CS-E12RKUAW CU-E12RKUA 9,000 (4,100-10,200) 12,000 (4,100-14,100) 1.3 425 23.0 13.0 11.0 230/208V, 1PH, 60Hz 3.2 / 3.6 5.1 / 5.7 690 (250-850) 1,120 (200-1,500) 15 15 11,500 (4,100-13,300) 13,800 (4,100-16,300) 1.7 450 22.5 12.5 11.0 230/208V, 1PH, 60Hz 4.2 / 4.7 5.6 / 6.3 920 (250-1,150) 1,250 (200-1,710) 15 15 Microprocessor Equipped Included CZ-RD516C-1 5 Speeds + Auto 24-hr Program Manual Automatic Included Optional Optional R-410A Electric Expansion Valve 42 / 29 / 26 48 Flare 1/4 3/8 Max. 65.6 Max. 49.2 Max. 49.2 Indoor Unit Outdoor Unit 11-7/16 21-9/32 34-9/32 30-23/32 8-7/16 11-13/32 20.0 82.0 Microprocessor Equipped Included CZ-RD516C-1 5 Speeds + Auto 24-hr Program Manual Automatic Included Optional Optional R-410A Electric Expansion Valve 44 / 35 / 32 49 Flare 1/4 1/2 Max. 65.6 Max. 49.2 Max. 49.2 Indoor Unit Outdoor Unit 11-7/16 21-9/32 34-9/32 30-23/32 8-7/16 11-13/32 20.0 82.0 E18RKUA Indoor Unit Outdoor Unit CS-E18RKUAW CU-E18RKUA 17,200 (5,800-19,800) 21,600 (5,800-22,000) 3.0 670 19.5 13.2 10.0 230/208V, 1PH, 60Hz 6.3 / 7.0 8.3 / 9.3 1,300 (430-1,600) 1,750 (380-1,800) 15 20 Microprocessor Equipped Included CZ-RD516C-1 5 Speeds + Auto 24-hr Program Automatic Automatic Included Optional Optional R-410A Electric Expansion Valve 47 / 39 / 36 49 Flare 1/4 1/2 Max. 100 Max. 49.2 Max. 49.2 Indoor Unit Outdoor Unit 11-7/16 31-5/16 42-5/32 34-15/32 9-15/32 12-5/8 26.0 132.0 Important: You must use refrigerant piping rated for R410a. *This is maximum elevation difference when the indoor unit is located above the outdoor unit. See p. 58 for additional information. Wired Remote Controller (CZ-RD516C-1) (Optional) E24RKUA Indoor Unit Outdoor Unit CS-E24RKUAW CU-E24RKUA 24,000 (5,800-27,200) 28,800 (5,800-29,200) 7.6 670 19.0 10.2 10.0 230/208V, 1PH, 60Hz 10.8 / 11.9 11.4 / 12.6 2,350 (430-2,720) 2,500 (380-2,660) 20 25 Microprocessor Equipped Included CZ-RD516C-1 5 Speeds + Auto 24-hr Program Automatic Automatic Included Optional Optional R-410A Electric Expansion Valve 48 / 40 / 37 51 Flare 1/4 5/8 Max. 100 Max. 49.2 Max. 49.2 Indoor Unit Outdoor Unit 11-7/16 31-5/16 42-5/32 34-15/32 9-15/32 12-5/8 26.0 132.0 28 AIR CONDITIONERS AND HEAT PUMP PRODUCTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

AIR CONDITIONERS AND HEAT PUMP PRODUCTS
28
E9RKUA / E12RKUA
E18RKUA / E24RKUA
Deluxe Series Wall-Mount Heat Pump
Cooling only operation may be configured during installation.
Pipe diameters listed below are for single zone only.
Multi zone pipe diameters on page 58.
WALL MOUNT HEAT PUMPS
Model No.
E9RKUA
E12RKUA
E18RKUA
E24RKUA
Unit Model No.
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
CS-E9RKUAW
CU-E9RKUA
CS-E12RKUAW
CU-E12RKUA
CS-E18RKUAW
CU-E18RKUA
CS-E24RKUAW
CU-E24RKUA
Performance & Electrical Ratings
Capacity
Cooling
Btu/h
9,000 (4,100–10,200)
11,500 (4,100–13,300)
17,200 (5,800–19,800)
24,000 (5,800–27,200)
Heating
Btu/h
12,000 (4,100–14,100)
13,800 (4,100–16,300)
21,600 (5,800–22,000)
28,800 (5,800–29,200)
Moisture Removal
High
Pints/H
1.3
1.7
3.0
7.6
Dry Air Flow
High
CFM
425
450
670
670
SEER
Cooling
23.0
22.5
19.5
19.0
EER
Cooling
13.0
12.5
13.2
10.2
HSPF
Heating
11.0
11.0
10.0
10.0
Power Supply
V, Phase, Hz
230/208V, 1PH, 60Hz
230/208V, 1PH, 60Hz
230/208V, 1PH, 60Hz
230/208V, 1PH, 60Hz
Running Amps
Cooling
A
3.2 / 3.6
4.2 / 4.7
6.3 / 7.0
10.8 / 11.9
Heating
A
5.1 / 5.7
5.6 / 6.3
8.3 / 9.3
11.4 / 12.6
Power Input
Cooling
W
690 (250–850)
920 (250–1,150)
1,300 (430–1,600)
2,350 (430–2,720)
Heating
W
1,120 (200–1,500)
1,250 (200–1,710)
1,750 (380–1,800)
2,500 (380–2,660)
Min. Circuit Ampacity
A
15
15
15
20
Max. Overcurrent Protection
A
15
15
20
25
Features
Controls
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Low Ambient Control
Equipped
Equipped
Equipped
Equipped
Wireless Controller
Included
Included
Included
Included
Wired Remote Controller(optional)
CZ±RD516C±1
CZ±RD516C±1
CZ±RD516C±1
CZ±RD516C±1
Fan Speeds
5 Speeds + Auto
5 Speeds + Auto
5 Speeds + Auto
5 Speeds + Auto
Timer
24±hr Program
24±hr Program
24±hr Program
24±hr Program
Air Deflection
Horizontal
Manual
Manual
Automatic
Automatic
Vertical
Automatic
Automatic
Automatic
Automatic
Advanced Air Purification
Features
Evaporator Guard Filter
Included
Included
Included
Included
PM2.5 (CZ±SA31P)
Optional
Optional
Optional
Optional
Anti Microbial (CZ±SA20P)
Optional
Optional
Optional
Optional
Refrigerant
R±410A
R±410A
R±410A
R±410A
Refrigerant control
Electric Expansion Valve
Electric Expansion Valve
Electric Expansion Valve
Electric Expansion Valve
Operation Sound
In (Hi / Me / Lo)
dB±A
42 / 29 / 26
44 / 35 / 32
47 / 39 / 36
48 / 40 / 37
Outdoor (Hi)
dB±A
48
49
49
51
Refrigerant Piping
(single zone)
Type
Flare
Flare
Flare
Flare
Discharge
inches
1/4
1/4
1/4
1/4
Suction
inches
3/8
1/2
1/2
5/8
Refrigerant Pipe Length
Ft.
Max. 65.6
Max. 65.6
Max. 100
Max. 100
Elevation Difference*
Outdoor Above
Ft.
Max. 49.2
Max. 49.2
Max. 49.2
Max. 49.2
Outdoor Below
Ft.
Max. 49.2
Max. 49.2
Max. 49.2
Max. 49.2
Dimensions & Weight
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
Height
inches
11±7/16
21±9/32
11±7/16
21±9/32
11±7/16
31±5/16
11±7/16
31±5/16
Width
inches
34±9/32
30±23/32
34±9/32
30±23/32
42±5/32
34±15/32
42±5/32
34±15/32
Depth
inches
8±7/16
11±13/32
8±7/16
11±13/32
9±15/32
12±5/8
9±15/32
12±5/8
Net Weight
Lbs.
20.0
82.0
20.0
82.0
26.0
132.0
26.0
132.0
Wireless
Controller
(Included)
Wireless
Controller
(Included)
Wired
Remote Controller
(CZ-RD516C-1)
(Optional)
Wired
Remote Controller
(CZ-RD516C-1)
(Optional)
Important:
You must use refrigerant piping rated for R410a.
*This is maximum elevation difference when the indoor unit is located above the outdoor unit. See p. 58 for additional information.
INDOOR UNIT
CS-E9RKUAW / CS-E12RKUAW
INDOOR UNIT
CS-E18RKUAW / CS-E24RKUAW
(E18 only)
OUTDOOR UNIT
CU-E9RKUA / CU-E12RKUA
OUTDOOR UNIT
CU-E18RKUA / CU-E24RKUA