Panasonic XE9WKUA Full Line Catalog - Page 38

Zone 1.5 Ton

Page 38 highlights

Multi-Zone Systems -5°F Heat Operation 2 Zone (1.5 Ton) CU-2E18SBU-5 Cooling Capacity: 16,700 (7,200 - 20,000) Btu/hr. Heating Capacity: 20,200 (7,200 - 24,600) Btu/hr. SEER Non-Ducted 19.0 / Ducted 19.0 EER Non-Ducted 12.55 / Ducted 12.55 HSPF Non-Ducted 9.5 / Ducted 9.0 Min/Max capacity 11,000 - 21,8000 Btu/hr. Connect 2 Indoor Units Wireless Controller (Included) Wired Remote Controller (CZ-RD516C-1) (Optional) Wireless Controller (Included) Wired Controller with 32 ft cable CZ-RD52CU (Optional) CZ-BT20U Grille Ordered Separately CU-2E18SBU-5 See Multi Zone Calculation and Selection Chart on pp. 42-43. Outdoor Unit MODEL NO. Performance Capacity Btu/h Air Circulation High CFM Number of Connectable Indoor Units SEER Non-Ducted / Ducted EER Non-Ducted / Ducted HSPF Non-Ducted / Ducted Electrical Rating Power Supply Running Ampere Power Input Maximum Fuse Size : MCA / MOCP V, Phase, Hz Non-Ducted / Ducted A W Amps Features Controls Fan Speeds Compressor Refrigerant / Amount Charged at Shipment Refrigerant Control Operation Sound Hi Refrigerant Tubing Connections Max. Allowable Tubing Length Refrigerant Tube Diameter Discharge (service value) Suction dB-A Type Ft. inch inch Adapter Required Dimensions & Weight Unit Dimensions H x W x D inch Net Weight Lbs. Cooling 16,700 (7,200~20,000) 6.6~6.0 / 6.6~6.0 1,330 48 Important: You must use refrigerant piping rated for R410a. See pages 57-60 for additional information. *Test Conditions based on AHRI 210/240 CU-2E18SBU-5 1,447 2 19.0 / 19.0 12.55 / 12.55 9.5 / 9.0 230V / 208V, 1PH, 60Hz 20 / 25 Microprocessor Variable Speed DC Inverter R-410A / 78.70 oz Electronic Expansion Valve Flare 164 per system (82 per indoor unit) 1/4" x 2 3/8" x 2 Indoor 12K Btu/hr. requires 1 CZ-MA1P-US 31-5/16" x 34-15/32" (+3-3/4) x 14-3/6" 157 Heating 20,200 (7,200~24,600) 8.5~7.8 / 8.5~7.8 1,750 49 38 AIR CONDITIONERS AND HEAT PUMP PRODUCTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

AIR CONDITIONERS AND HEAT PUMP PRODUCTS
38
Connect 2 Indoor Units
Wireless
Controller
(Included)
Wired
Remote Controller
(CZ-RD516C-1)
(Optional)
Zone (1.5 Ton)
2
See Multi Zone Calculation and Selection Chart on pp. 42-43.
Important:
You must use refrigerant piping rated for R410a. See pages 57-60 for additional information.
*Test Conditions based on AHRI 210/240
CU-2E18SBU-5
Cooling Capacity: 16,700 (7,200 - 20,000) Btu/hr.
Heating Capacity: 20,200 (7,200 - 24,600) Btu/hr.
SEER Non-Ducted 19.0
/ Ducted 19.0
EER
Non-Ducted 12.55 / Ducted 12.55
HSPF Non-Ducted 9.5
/ Ducted 9.0
Min/Max capacity
11,000 - 21,8000 Btu/hr.
MODEL NO.
CU-2E18SBU-5
Performance
Cooling
Heating
Capacity
Btu/h
16,700 (7,200~20,000)
20,200 (7,200~24,600)
Air Circulation
High
CFM
1,447
Number of Connectable Indoor Units
2
SEER
Non±Ducted / Ducted
19.0 / 19.0
EER
Non±Ducted / Ducted
12.55 / 12.55
HSPF
Non±Ducted / Ducted
9.5 / 9.0
Electrical Rating
Power Supply
V, Phase, Hz
230V / 208V, 1PH, 60Hz
Running Ampere
Non±Ducted / Ducted
A
6.6~6.0 / 6.6~6.0
8.5~7.8 / 8.5~7.8
Power Input
W
1,330
1,750
Maximum Fuse Size : MCA / MOCP
Amps
20 / 25
Features
Controls
Microprocessor
Fan Speeds
Variable Speed
Compressor
DC Inverter
Refrigerant / Amount Charged at Shipment
R±410A / 78.70 oz
Refrigerant Control
Electronic Expansion Valve
Operation Sound
Hi
dB±A
48
49
Refrigerant Tubing Connections
Type
Flare
Max. Allowable Tubing Length
Ft.
164 per system (82 per indoor unit)
Refrigerant Tube Diameter
(service value)
Discharge
inch
1/4” x 2
Suction
inch
3/8” x 2
Adapter Required
Indoor 12K Btu/hr. requires 1 CZ±MA1P±US
Dimensions & Weight
Unit Dimensions
H x W x D
inch
31±5/16” x 34±15/32” (+3±3/4) x 14±3/6”
Net Weight
Lbs.
157
-5°F Heat Operation
CU-2E18SBU-5
Wireless
Controller
(Included)
Wired Controller
with 32 ft cable
CZ-RD52CU
(Optional)
CZ-BT20U
Grille Ordered
Separately
Outdoor Unit
Multi-Zone Systems